If |
| Then | |
|
|
|
|
The green power light doesn’t go |
| Test the outlet by plugging in a radio or a | |
on and the orange light on the |
| lamp. | |
power switch also doesn’t go on |
|
| |
|
|
| |
The green power light is on, but |
| The outlet is not functioning, is miswired or | |
the orange power switch light is |
| improperly grounded. Have it repaired or use | |
off . |
| another outlet. | |
|
|
|
|
The green power light is off but |
| Stop the installation. Turn off the control | |
the orange power switch light is |
| unit, unplug it from the ac outlet, and contact | |
on and the outlet is working |
| your equipment supplier for assistance. | |
properly |
|
| |
|
|
| |
The red warning light continually |
| Unplug the power cord and plug it in again. | |
flashes or remains lit |
|
| |
|
|
| |
The red warning light continues to |
| Set the power switch to Off, and make sure | |
flash or remains lit |
| that each module is seated firmly in its slot. | |
|
|
| Then set the power switch to On. |
|
|
| |
If the red warning light still |
| Stop the installation. Contact your equipment | |
continually flashes or remains lit |
| supplier for assistance. | |
|
|
|
|
When the unit is on and only the green power light and orange power switch light remain on, the control unit is working correctly. Before you connect any lines to the control unit, turn the power off.
CONNECT THE OUTSIDE As shown on the label attached to the power module, control unit line jacks
LINES TO THE CONTROL are designated by the letters A through H. The A line jack is the second from
UNITthe top, B is third from the top, C is fourth, and so on. The topmost line jack, the Auxiliary jack, is described under "Auxiliary Line Telephone" in this manual.
Connect the outside lines to the line jacks in an unbroken sequence. If you start with A, for example, the next connection should be B, the next C, and so on. Although any outside line can be connected to any line jack, do not skip jacks once you have begun. If you start with B, the next connection should be C, followed by D, and so on. This simplifies future line administration.
Also, group special line types such as WATS lines together in the sequence, and place personal lines, if any, at the end of the sequence.
You need the following items to connect the control unit to the jacks for your outside lines, whether they appear at the jack field, or at the network interface.
●A completed System Configuration Form (Figure 14)
●A
Use a