FIGURE 14 A System Configuration Form.
See Figure 15 and follow this procedure to connect your outside lines:
1Refer to your System Configuration Form when connecting the outside lines you’ve assigned to each line jack on the control unit. The outside line numbers are the telephone numbers listed at the network interface.
2Mark or label a D2R cord on both ends with "A."
3Plug one end of the line cord into the control unit jack labeled "A."
4Plug the other end of the cord into the network interface or jack field that corresponds with the telephone number shown on your System Configuration form.
5Repeat steps 2 through 4 for lines B through H or until you have connected all your outside lines to the control unit.
CAUTION: Do not run cords inside or on top of air plenums or ducts, along hot pipes, or across walkways. If you use staples to attach the cords to a wall, be careful not to pierce the cords.