WARNING
Turn controls and gas source or tank OFF when not in use.
CAUTION
If ignition does NOT occur in 5 seconds, turn the burner controls OFF, wait 5 minutes and repeat the lighting procedure. If the burner does not ignite with the valve open, gas will continue to flow out of the burner and could accidently ignite with risk of injury.
sDo not lean over grill while lighting.
1.Turn all burner control valves. Open lid during lighting. Turn on gas at LP cylinder.
2.Place lit match into match holder, then into side of grill bottom (as shown below).
3.Push in and turn IGNITION BURNER knob to
4.To ignite right burner, turn right knob to
After Lighting: Turn knobs to HI for
Burner Flame Check
•Light burner, rotate knobs from HIGH to LOW. You should see a smaller flame in LOW position than seen on HIGH. Always check flame prior to each use. If only low flame is seen refer to "Sudden drop or low flame" in the Troubleshooting Section.
HI
LO
Hose Check
•Before each use, check to see if hoses are cut, worn or kinked. Replace damaged hoses before using grill. Use only valve/hose/regulator specified in the Parts List.
Normal | Kinked |
Hose | Hose |
Turning Grill Off
•Turn all knobs to OFF position. Turn LP tank off by turning OPD hand wheel clockwise to a full stop.
Ignitor Check
•Turn gas off at LP tank. Press and hold ignitor button. "Click" should be heard and spark seen each time between collector box or burner and electrodes. See "Troubleshooting" if no click or spark.
Valve Check
•Important: Make sure gas is off at LP tank before checking valves. Knobs lock in OFF position. To check valves, first push in knobs and release, knobs should spring back. If knobs do not spring back, replace valve assembly before using grill. Turn knobs to LO position then turn back to OFF position. Valves should turn smoothly.
12