Weber 55826 Safe Handling Tips for Liquid Propane GAS Cylinders, Liquid Propane LP Cylinders

Page 11

GAS INSTRUCTIONS

11

 

 

 

SAFE HANDLING TIPS FOR LIQUID PROPANE GAS CYLINDERS

Liquid Propane (LP) gas is a petroleum product as are gasoline and natural gas. LP gas is a gas at regular temperatures and pressures. Under moderate pressure, inside a cylinder, LP gas is a liquid. As the pressure is released, the liquid readily vaporizes and becomes gas.

LP gas has an odor similar to natural gas. You should be aware of this odor.

LP gas is heavier than air. Leaking LP gas may collect in low areas and prevent dispersion.

To fill, take the LP cylinder to an RV center, or look up “gas-propane” in the phone book for other sources of LP gas.

WARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight. IMPROPER FILLING IS DANGEROUS.

Air must be removed from a new LP cylinder before the initial filling. Your LP dealer is equipped to do this.

The LP cylinder must be installed, transported and stored in an upright position. LP cylinders should not be dropped or handled roughly.

Never store or transport the LP cylinder where temperatures can reach 125° F (too hot to hold by hand - for example: do not leave the LP

cylinder in a car on a hot day).

Note - A refill will last about 20 hours of cooking time at normal use. The fuel scale will indicate the propane supply so you can refill before running out. You do not have to run out before you refill.

Treat “empty” LP cylinders with the same care as when full. Even when the LP tank is empty of liquid there still may be gas pressure in the cylinder. Always close the cylinder valve before disconnecting.

CAUTION: When transporting the LP cylinder make sure the plastic dust cover is in place over the valve. This will keep dust and dirt from the threaded portion of the valve.

Do not use a damaged LP cylinder. Dented or rusty LP cylinders or LP cylinders with a damaged valve may be hazardous and should be replaced with a new one immediately.

Liquid Propane (LP) Cylinder(s)

The joint where the hose connects to the LP cylinder must be leak tested each time the LP cylinder is reconnected. For example, test each time the LP cylinder is refilled.

Be sure the regulator is mounted with the small vent hole pointed downward so that it will not collect water. This vent should be free of dirt, grease, bugs etc.

The gas connections supplied with your Weber® gas barbecue have been designed and tested to meet 100% CSA and ANSI requirements.

WARNING: Replacement LP tanks must match the regulator connection supplied with this barbecue.

Liquid Propane Cylinder requirements

Check to be sure cylinders have a D.O.T. certification (1), and date tested

(2)is within five years. Your LP gas supplier can do this for you.

All LP tank supply systems must include a collar to protect the cylinder valve.

The LP cylinder must be a 20-lb. size approximately (18 1/4 inches high, 12 1/4 inches in diameter).

The cylinder should be constructed and marked in accordance with the Specifications for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-

B339, Cylinders, Spheres and Tubes or Transportation of Dangerous Goods; and Commission, as applicable.

In Canada

Liquid Propane Cylinder requirements

Note: Your retailer can help you match a replacement tank to your barbecue

The LP cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders, T.C.

(1)

DOT 4BA240

00/05

(2)

Image 11
Contents LP US English Genesis GAS GrillContents Liquid Propane GAS Units only For replacement parts call WarrantyCustomer Service Center Roselle Road, Suite Schaumburg, IL Operating For Installation in CanadaGeneral Instructions Storage AND/OR NonuseCooking CleaningCheck That ALL Burner Valves are OFF Connecting the Liquid Propane CylinderGAS Instructions Important LP Cylinder InformationRemove Control Panel and Burner Control Knobs GAS InstructionsCheck Silver a & B Gold B Platinum BCheck for GAS Leaks Removal of the LP cylinder Gold C Platinum CRefilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankCanada Liquid Propane Cylinder requirements Safe Handling Tips for Liquid Propane GAS CylindersLiquid Propane LP Cylinders Liquid Propane Cylinder requirementsMain Burner Lighting Operating InstructionsSilver a & B Silver C Gold B & C LightingManual Lighting Main Burner Lighting Silver a & BSilver C Gold B & C Platinum B & C Manual Lighting For Side Burner ModelsLighting the Side Burner Lighting with IgniterProblem Check Cure TroubleshootingSide Burner Maintenance Side Burner TroubleshootingWeber Spider /INSECT Screens MaintenanceAnnual Maintenance Inspection and cleaning of the Spider/Insect screensTurn off the gas supply Main Burner Cleaning ProcedureMain Burner Flame Pattern Replacing Main BurnersGenesis C Genesis a & BWEBER-STEPHEN Products CO