Weber 55023 1199 manual Install Gas Supply General Specifications for Piping, Gas Line Piping

Page 14

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installa- tions. In absence of Local Codes, you must con- firm to the latest edition of ANSI Z223.1. WE REC-

OMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifi- cations.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizon- tally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to

rigid, permanent construction.

￿WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

 

Gas supply

Inside wall

 

Outside wall

 

 

Shut off

Quick Disconnect

Locking shut off

 

Gas Line Piping

If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet.

Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thick- ness of .062 inch; or standard weight (schedule 40) steel or wrought iron pipe.

Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfide per 100 cubic feet of gas.

Plastic tubing is suitable only for outdoor, under- ground use.

Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.

Underground piping must have a minimum of 18" cover

Test Connections

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1

￿DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

C-2

Image 14
Contents Genesis GOLD-B Liquid Propane GAS Units only Warranty Customer Service Center South Hicks Road Palatine, ILContents Storage For Installation in CanadaOperating Gas Supply Testing Genesis Gold-B NG Manifold, Hose and regulator assembled Page Remove Packaging from Grill Remove Grill from Lower PackagingPage Assembly Instructions Install the slide out bottom trayInstall the bottom shelf Installing the Warm-Up BasketInstalling the warming rack Install the condiment basketInstalling Work Surfaces Gas Connection Guidelines Remove the control panelTest Connections Install Gas Supply General Specifications for PipingGas Line Piping Check for gas leaks Reinstall control panel after checking for gas leaks Install Right Work SurfaceLighting To ExtinguishManual Lighting Storage CleaningCooking Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Replacing Main Burners Crossover Ignition System Operations Orange flame, in conjunction with Flame is low when burner is onBurners burn with a yellow or Smell of gas