Weber GENESIS GOLDB Gas Grill, 55023 1199 manual Check for gas leaks

Page 15

Check for gas leaks

￿DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion which can cause seri- ous bodily injury or death and damage to property.

￿WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting. Note - All factory-made connections have been thoroughly checked for gas leaks. The burners have been flame-tested. As a safety precaution however, you should recheck all fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may loosen or damage a gas fitting.

￿WARNING: Perform these leak checks even if your barbecue was dealer or store assembled. You will need: a soap and water solution, and a rag or brush to apply it.

To perform leak checks: Slide back the collar of the quick disconnect. Push male fitting of the hose into the quick disconnect, and maintain pressure(1). Slide the collar closed(2). If it does not engage or lock, repeat procedure. Gas will not flow unless the quick discon- nect is properly engaged.

(1)

(2)

Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

￿WARNING: Do not ignite burners when leak checking.

Check:

1) Hose to manifold connection.

￿WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

2)Valves to manifold connection

3)Hose to quick disconnect connection

￿WARNING: If there is a leak at connections(2) or(3) turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact the Customer Service Repre- sentative in your region using the contact informa- tion sheet provided with your manual.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(1)

(2)

(3)

C-3

Image 15
Contents Genesis GOLD-B Liquid Propane GAS Units only Customer Service Center South Hicks Road Palatine, IL WarrantyContents For Installation in Canada Operating Gas Supply TestingStorage Genesis Gold-B NG Manifold, Hose and regulator assembled Page Remove Grill from Lower Packaging Remove Packaging from GrillPage Install the slide out bottom tray Assembly InstructionsInstall the condiment basket Installing the Warm-Up BasketInstalling the warming rack Install the bottom shelfRemove the control panel Installing Work Surfaces Gas Connection GuidelinesInstall Gas Supply General Specifications for Piping Gas Line PipingTest Connections Check for gas leaks Install Right Work Surface Reinstall control panel after checking for gas leaksTo Extinguish LightingManual Lighting Cleaning CookingStorage Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceGeneral Maintenance Main Burner Cleaning ProcedureWeber Spider Stopper Guards Replacing Main Burners Crossover Ignition System Operations Smell of gas Flame is low when burner is onBurners burn with a yellow or Orange flame, in conjunction with