OPERATING INSTRUCTIONS

Lighting

Summary lighting instructions are on the control panel.

mDANGER

Failure to open lid while igniting the barbecue, or not waiting 5 minutes to allow the gas to clear if the barbecue does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

Crossover Ignition System

Note - The Crossover Ignition System ignites the Front burner with a spark from the igniter electrode inside the Gas Catcher Ignition Chamber. You generate the energy for the spark by pushing the Crossover Ignition Button until it clicks.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement manifold assembly. Order from Weber- Stephen Products Co., Customer Service Center or authorized dealer.

1

Crossover Ignition System

 

3

8

 

 

6

 

4

7 2

 

5

 

Figure 1

 

1)Open the lid. Figure 1.

2)Check that the fuel scale reads more than “E”. Note - E = empty; F = full.

3)Make sure all burner control knobs are turned OFF. (Push each knob down and turn clockwise.)

mWARNING: The burner control knobs must be in the

OFF position before turning on the LP tank valve. If they are not in the OFF position, when you turn on the LP tank valve, the excess flow control will activate, limiting the flow of gas from the LP tank. If this should occur, turn OFF the LP tank valve and burner control knobs and start over.

mDANGER

When the excess flow control is activated, a small amount of gas is still flowing to the burners. After turning OFF the tank and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame-up which can cause serious bodily injury or death.

4)Turn the tank on by turning the tank valve counterclockwise.

mWARNING: Do not lean over open barbecue. Keep your face and body at least one foot away from the matchlight hole when lighting the barbecue.

5)Push Front burner control knob down and turn to START/ HI.

6)Push the Crossover Ignition Button several times, so it clicks each time.

7)Check that the burner is lit by looking through the matchlight hole on the front of the cooking box.

mWARNING: If the burner does not light, turn the

Front burner control knob to OFF and wait 5 minutes to let the gas clear before you try again or try to light with a match.

8)After the FRONT burner is lit you can turn on the other burners.

Note - Always light the FRONT burner first. The other burners ignite from the FRONT burner.

To Extinguish

Turn gas supply OFF at the source, then push down and turn each burner control knob clockwise to OFF.

22

Image 22
Contents 900 LP Gas Barbecue LP GAS Units only Warranty Patents and Trademarks Contents Storage For Installation in CanadaGeneral Instructions Operating areaCheck package contents AssemblyStep REB Check contents of hardware packs Assemble wheel frame Assemble top frameInstall tubing plugs Continue frame assemblyAdd front panel Add cooking box Install manifold bracket Install tank panel assembly and frame connectorAdd fuel scale assembly Install igniterSet LP fuel scale MCAUTION Do not remove adjustment wing nut from tank scaleFill LP tank Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksSlide the bottom tray onto the mounting rails under Install Flavorizer Bars and Cooking GratesInstall the bottom tray Cooking box with finger grip toward you. Figure Install Lid Add tool holders, control panel and burner control knobsInstall swing table MWARNING The load limit for the swing table is 30 poundsComplete accessory installation Lighting To ExtinguishManual Lighting Storage and/or Nonuse Periodic CleaningCooking Storage and/or NonuseCast Iron Cooking Grates Refilling the LP tank Connecting the filled LP tankRemoval of the LP tank Male fitting Regulator Safe handling tips for LP Gas Liquid Propane LP TanksInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMWARNING Do not ignite burners while leak checking MCAUTION Do not enlarge the burner ports when cleaning General MaintenanceMain Burner Cleaning Procedure Weber Spider Stopper GuardsTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Burner does not light, or flame is low in High position NCAUTION Do not line the bottom tray with aluminum foil11-12 65 51-53 56-57 Parts List Final Word Thanks