Weber Gold B Reinstall control panel after checking for gas leaks, Install Right Work Surface

Page 17

Reinstall control panel (after checking for gas leaks)

(1)Set the control panel in place over both sides of the frame. Hold the crossover ignition button up while setting the control panel in place.

(2)Line up the control panel with the white plastic plugs in the frame brace. Insert screws and tighten with a Phillips screwdriver until snug. Do not overtighten.

(3)Push each of the burner control knobs onto their valve.

(4)Reinstall Side Burner cover.

(1)

(3)

(2)

Install Right Work Surface

You will need right work surface, two 1/2 inch bolts, two nylon washers and a 7/16 inch or adjustable wrench.

Insert the right work surface tabs in the slots In the frame(1). Slip washers on the bolts and insert the bolts as shown(2). Tighten

(1)(2)

C-5

Image 17
Contents Owners Guide Liquid Propane GAS Units only Customer Service Center South Hicks Road Palatine, IL WarrantyContents Operating For Installation in CanadaStorage Genesis Gold-B LP Manifold, Hose and regulator assembled Page Remove Grill from Lower Packaging Remove Packaging from GrillPage Install the slide out bottom tray Assembly InstructionsInstalling the warming rack Installing the Warm-Up BasketInstall the bottom shelf Install the condiment basketFill liquid propane cylinder You will need burner control knobsHang filled liquid propane cylinder on fuel gauge Important LP Cylinder InformationRemove the control panel Page Install Right Work Surface Reinstall control panel after checking for gas leaksTo Extinguish LightingStill flowing to the burners. After turning Manual LightingOFF the cylinder and burner control Knobs, wait at least 5 minutes for the gasStorage and/or Nonuse CleaningCooking Pane Cylinder Refilling the Liquid ProTo Connect the hose to the cylinder Connection. Using a wrench could damageRegulator coupling and could cause a leak Liquid Propane CylinderLiquid Propane Gas Cyl Safe handling tips forInders Liquid Propane LP CylindersInspection and Cleaning of the Weber Annual MaintenanceSpider Stopper Guards Water, may be slightly corrosive, all connectionsMain Burner Cleaning Procedure General MaintenanceMain Burner Flame Pattern Weber Spider Stopper GuardsPositioned properly over the valve orifices2 Replacing Main BurnersCrossover Ignition System Operations Flame is low when burner is on Barbecue temperature onlyBurners burn with a yellow or Orange flame, in conjunction with