Weber Gold B Safe handling tips for, Liquid Propane Gas Cyl, Inders, Liquid Propane LP Cylinders

Page 23

Safe handling tips for

Liquid Propane (LP) Cylinder(s)

The joint where the hose connects to the LP cylinder

Liquid Propane Gas Cyl-

must be leak tested each time the LP cylinder is

 

inders

reconnected. For example, test each time the LP

cylinder is refilled.

 

Liquid Propane (LP) gas is a petroleum product as

Be sure the regulator is mounted with the small vent

hole pointed downward so that it will not collect water.

are gasoline and natural gas. LP gas is a gas at

This vent should be free of dirt, grease, bugs etc.

regular temperatures and pressures. Under moderate

The LP cylinder and connections supplied with your

pressure, inside a cylinder, LP gas is a liquid. As the

Weber Gas Barbecue have been designed and tested

pressure is released, the liquid readily vaporizes and

to meet government, American Gas Association, and

becomes gas.

Underwriters Laboratories requirements.

LP gas has an odor similar to natural gas. You

 

should be aware of this odor.

(1)

LP gas is heavier than air. Leaking LP gas may

collect in low areas and prevent dispersion.

 

To fill, take the LP cylinder to an RV center, or look

 

up “gas-propane” in the phone book for other sources

 

DOT 4BA240

 

of LP gas.

 

00/00

 

 

m WARNING: We recommend that your LP cylinder

 

 

 

 

be filled at an authorized LP gas dealer, by a

 

 

 

 

qualified attendant, who fills the tank by weight.

 

 

 

 

IMPROPER FILLING IS DANGEROUS.

 

 

 

 

mWARNING: If you exchange your LP cylinder,

make sure you get a similar tank in return. Your LP

 

(2)

cylinder is equipped with a quick closing coupling

 

 

 

 

or type 1 valve and an OPD (Overfilling Prevention

 

Liquid Propane Cylinder requirements

 

Device). Other LP cylinders may not be compatible

 

Replacement LP cylinders supplied by Weber satisfy

 

with your barbecue connection.

 

the above requirements. Check to be sure other

 

Air must be removed from a new LP cylinder before

 

 

cylinders have a D.O.T. certification(1), and date

 

the initial filling. Your LP dealer is equipped to do this.

 

 

tested(2) is within five years. Your LP gas supplier can

 

The LP cylinder must be installed, transported and

 

 

do this for you.

stored in an upright position. LP cylinders should not

 

 

If you have questions about spare LP cylinders

 

be dropped or handled roughly.

 

 

contact the Customer Service Representative in

 

Never store or transport the LP cylinder where

 

 

your region using the contact information sheet

 

temperatures can reach 125° F (too hot to hold by

 

 

provided with your manual.

hand - for example: do not leave the LP cylinder in a

 

 

All LP tank supply systems must include a collar to

car on a hot day).

 

 

protect the cylinder valve.

Note - A refill will last about 20 hours of cooking time

 

 

The LP cylinder must be a 20-lb. size (18 1/4 inches

at normal use. The fuel scale will indicate the propane

 

 

high, 12 1/4 inches in diameter).

supply so you can refill before running out. You do not

 

The LP cylinder must be constructed and marked in

 

have to run out before you refill.

 

 

accordance with the specifications for LP gas cylinders

 

Treat “empty” LP cylinders with the same care as

 

 

of the U.S. Department of Transportation (D.O.T.).

 

when full. Even when the LP tank is empty of liquid

 

 

 

 

 

there still may be gas pressure in the cylinder. Always

 

 

 

 

close the cylinder valve before disconnecting.

 

 

 

 

m CAUTION: When transporting the LP cylinder

 

 

 

 

make sure the plastic dust cover is in place over

 

 

the valve. This will keep dust and dirt from the

 

 

 

 

threaded portion of the valve.

 

 

 

 

Do not use a damaged LP cylinder. Dented or rusty

 

 

 

 

LP cylinders or LP cylinders with a damaged valve

 

 

 

 

may be hazardous and should be replaced with a new

 

 

 

 

one immediately.

 

 

 

 

 

 

 

D-6

Image 23
Contents Owners Guide Liquid Propane GAS Units only Customer Service Center South Hicks Road Palatine, IL WarrantyContents Operating For Installation in CanadaStorage Genesis Gold-B LP Manifold, Hose and regulator assembled Page Remove Grill from Lower Packaging Remove Packaging from GrillPage Install the slide out bottom tray Assembly InstructionsInstall the condiment basket Installing the Warm-Up BasketInstalling the warming rack Install the bottom shelfFill liquid propane cylinder You will need burner control knobsHang filled liquid propane cylinder on fuel gauge Important LP Cylinder InformationRemove the control panel Page Install Right Work Surface Reinstall control panel after checking for gas leaksTo Extinguish LightingKnobs, wait at least 5 minutes for the gas Manual LightingStill flowing to the burners. After turning OFF the cylinder and burner controlStorage and/or Nonuse CleaningCooking Pane Cylinder Refilling the Liquid ProLiquid Propane Cylinder Connection. Using a wrench could damageTo Connect the hose to the cylinder Regulator coupling and could cause a leakLiquid Propane LP Cylinders Safe handling tips forLiquid Propane Gas Cyl IndersWater, may be slightly corrosive, all connections Annual MaintenanceInspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Main Burner Flame PatternPositioned properly over the valve orifices2 Replacing Main BurnersCrossover Ignition System Operations Orange flame, in conjunction with Barbecue temperature onlyFlame is low when burner is on Burners burn with a yellow or