Panasonic manual Technical Data, PWW 4000 series Type 4030 4050, PWW 4000 series Type 4080 4100

Page 9

Technical Data

PWW 4000 series

 

 

 

 

 

 

 

 

 

 

Type

 

4030 - 3

4030 - 4

4050 - 3

4050 - 4

 

 

 

 

 

 

Electrical connection

V

400 / 3~ N

400 / 3~ N

400 / 3~ N

400 / 3~ N

Frequency

Hz

50

50

50

50

Power consumption

kW

0.13

/ 0.10

0.13

/ 0.10

0.26

/ 0.18

0.26

/

0.18

Rated current

A

0.26

/ 0.16

0.26

/ 0.16

0.52

/ 0.29

0.52

/

0.29

Speed

U/min

1340

/ 1040

1340

/ 1040

1360

/ 1020

1360

/

1020

Air capacity

m³/h

2050

/ 1640

1850

/ 1500

3400

/ 2870

3150

/

2770

Sound pressure level 1)

dB(A)

53

/ 48

55

/ 49

55

/ 51

58

/

54

Heating medium connection

inch

R1"

R1¼"

R1"

R1¼"

 

 

 

 

 

 

Heating medium

 

Pump warm water or pump hot water up to max. 130 °C

Operating pressure

bar

16

 

 

 

16

16

16

Weight

kg

26

27

34

36

 

 

 

 

 

 

 

 

 

1) Measurement at intervals of 5 m, measuring room volume 800 m³, average reverberation time 1.4 s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PWW 4000 series

 

 

 

 

 

 

 

 

 

 

Type

 

4080 - 3

4080 - 4

4100 - 3

4100 - 4

 

 

 

 

 

 

Electrical connection

V

400 / 3~ N

400 / 3~ N

400 / 3~ N

400 / 3~ N

Frequency

Hz

50

50

50

50

Power consumption

kW

0.42

/ 0.28

0.42

/ 0.28

0.76

/ 0.47

0.76

/

0.47

Rated current

A

0.76

/ 0.46

0.76

/ 0.46

1.50

/ 0.81

1.50

/

0.81

Speed

U/min

880

/ 670

880

/ 670

870

/ 650

870

/

650

Air capacity

m³/h

5400

/ 4300

4730

/ 4700

8250

/ 6620

7670

/

6180

Sound pressure level 1)

dB(A)

55

/ 49

55

/ 49

58

/ 54

59

/

55

Heating medium connection

inch

R1¼"

R1¼"

R1½"

R1½"

 

 

 

 

 

 

Heating medium

 

Pump warm water or pump hot water up to max. 130 °C

Operating pressure

bar

16

 

 

 

16

16

16

Weight

kg

47

51

60

68

 

 

 

 

 

 

 

 

 

 

 

1) Measurement at intervals of 5 m, measuring room volume 800 m³, average reverberation time 1.4 s

9

Image 9
Contents Edition GB P08 Remko PWWPage Warm Water Wall-Mounted Heating Units ContentsAssembly Instructions Safety InstructionsElectrical installation Connection to the heating systemBrackets Unit AssemblyKO bracket Important information about frost protectionElectric Connection Sample AssembliesCustomer Service GuaranteeInitial Operation Maintenance Service and CareTechnical Data PWW 4000 series Type 4030 4050PWW 4000 series Type 4080 4100 Accessories Air outlet accessoriesAir intake accessories Adjustment motor open/closed Motor control units, 5-speed Connecting the fan motorFrost protection mechanism Msrd 2.5 switching unit Wiring diagram Switching on again after a problem SW 2.1 D switching unitWiring diagram of the thermal contacts FunctionalityAir supply flap Night Day Thermal Frost SW 2.2 DSK switching unit