Weber 42371 manual Replacing Main Burners

Page 17

MAINTENANCE

Replacing Main Burners

1.Your Summit® gas grill must be OFF and cool.

2.Turn gas OFF at source.

3.Disconnect regulator.

4.Remove cooking grates.

5.Remove Smoker box.

6.Remove Flavorizer® bars.

7.To remove control panel refer to “Remove the control panel” under “Check for Gas Leaks.”

8.Disconnect all ignition wires from the Ignition Module.

9.Remove screws from the manifold assembly:

(a) Locate the screws on both sides of the manifold frame. (b) Remove the screws from manifold frame.

(a)

(a)

(b)

(b)

10. Pull manifold assembly out from the manifold frame.

-

+

-

+

2

1

1 = White Tab with Black Wire

2 = Yellow Tab with Black Wire

17

Image 17
Contents 42371 US 04/01/04 LP US English BUILT-IN LP GAS Grill Owners GuideLiquid Propane GAS Units only Warranty WarrantyStorage AND/OR Nonuse OperatingGrilling Methods CleaningGeneral Instructions GAS Instructions Connecting the Liquid Propane CylinderImportant LP Cylinder Information Fill liquid propane cylinderTo Connect the hose to the cylinder Remove control panel Check for GAS LeaksReinstall control panel Safe handling tips for Liquid Propane Gas Cylinders Removal of the LP cylinderLiquid Propane LP Cylinders Refilling the Liquid Propane CylinderFlavorizer system Liquid Propane Cylinder requirementsFor Canada only Liquid Propane Cylinder requirements Direct cooking Operating InstructionsLighting Grilling Tips & Helpful HintsManual Lighting To ExtinguishOperating Instructions Problem Check Cure Main Burner TroubleshootingAnnual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider /INSECT ScreensReplacing Main Burners Valve orifices Check proper assembly before fastening manifold in placeParts required 1 AA alkaline battery per igniter