GAS INSTRUCTIONS
WARNING: Do not ignite burners when leak checking.
Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
Check:
1) Gas
WARNING: If there is a leak at connection (1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.
If a leak persists after
2)Regulator to cylinder connection.
3)Hose to regulator connection.
4)Valves to manifold connections.
WARNING: If there is a leak at connections (2, 3, or 4), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual.
When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.
(1)
Reinstall control panel
Parts required: control panel, screws, and burner control knobs.
Place the control panel back onto the control panel brackets on either side of the front of the cooking box. Line up screws with screw holes on both the control panel and control panel brackets. Tighten screws.
Reinstall burner control knobs & igniter wires (if necessary).
(1) |
(2) |
Place corresponding control knobs down onto the valve stems. From the underside of the control panel, replace the two wires (1, 2) of each igniter.
(2)
(3)
(4)
- | + |
- | + |
2
1
1 = White Tab with Black Wire
2 = Yellow Tab with Black Wire
8