Brinkmann 7741 Series owner manual Lighting Instructions, Lighting the Main Burners

Page 11

WARNING

Read, understand and follow all warnings and instructions contained in this manual. DO NOT skip any of the warnings and instructions contained in the preceding sections of this manual.

WARNING

LIGHTING INSTRUCTIONS:

Follow the instructions exactly.

1.OPEN THE GRILL LID before attempting to light a burner so that fumes do not accumulate inside the grill. An explosion could occur if grill lid is down.

2.Check that all burner control knobs and the cylinder valve are turned to the "OFF" position.

3.Turn on the fuel supply by rotating the cylinder valve knob counter-clockwise to full open.

4.DO NOT stand with head, body, or arms over the grill when lighting.

LIGHTING THE MAIN BURNERS:

1. Open lid before lighting burner.

2.Make sure all control knobs are in the "OFF" position.

3.Select burner to be lit. Push and turn control knob of that burner to HIGH and continue to push knob in for 2 to 3 seconds to light burner.

4. If ignition does NOT occur in 5 seconds, turn control knob to OFF, wait 5 minutes to allow gas to dissipate and repeat lighting procedure.

5. Repeat Steps 3 & 4 for lighting each burner.

6.Refer to owner’s manual for match lighting procedure.

7.To turn off, turn control knob clockwise until it locks in OFF position.

Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner, or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and Hose/Regulator to Grill.

MATCH LIGHTING THE MAIN BURNERS:

1.Open lid before lighting.

2.Turn the burner control knobs to "OFF".

3.Place a paper match in the end of the matchlighter. Strike the match and place approximately 1/2" (1 to 2 cm) from the burner lighting hole. Burner lighting hole is located inside left cabinet.

4.Turn on the FAR LEFT burner control knob to the "HIGH" position. The burner should light within 5 seconds.

5.If the burner does not light, turn the control knob to "OFF" and wait 5 minutes for gas to dissipate and repeat lighting procedure.

6.Once lit, light adjacent burners in sequence by pressing in and rotating the control knob to the "HIGH" position.

Match Lighting

Hole

Match-

Lighter

7.If the burner does not light within the first few attempts of match lighting, there is a problem with the gas supply. Turn off the gas at the burner and cylinder. DO NOT attempt to operate the grill until the problem is found and corrected. See "Trouble Shooting" section of this manual.

10

Image 11
Contents Aviso Para EL Instalador Important Safety Table of Contents General Warnings LP GAS Cylinder not Supplied with this Grill Installation InformationCylinder Specifications Hose and Regulator Installing the LP GAS Cylinder Onto the GrillRegulator Resetting Procedure Filling the LP GAS CylinderConnecting Hose and Regulator Connecting Hose and Regulator to AN LP GAS CylinderChecking for Leaks Leak TestingWhen to Perform a Leak Test PRE-START Check List Match Lighting the Main Burners Lighting InstructionsLighting the Main Burners Lighting the Side Burner Lighting the Rotisserie BurnerMatch Lighting the Rotisserie Burner Turning OFF the Grill Match Lighting the Side BurnerControlling FLARE-UPS Operating the GrillBreaking in Your Grill Preheating the GrillSide Burner Rotisserie CookingHelpful Hints CleanlinessGrilling to Proper Temperature Burner ASSEMBLY/MAINTENANCE Cleaning and MaintenanceBefore Storing Your Grill Cooking GrillsHeat Distribution Plates Transporting and StorageTrouble Shooting Frequently Asked Questions Frequently Asked Questions Parts List Assembly InstructionsFor Missing PARTS, Please Call Customer Service AT Parts BAG Contents Step Proper ground Step ProSeries 7741 Assembled Peligro Importantes Advertencias DE SeguridadÍndice Advertencias Generales Información DE Instalación Especificaciones DEL Cilindro Procedimiento DE Reposición DEL Regulador Llenado DEL Cilindro DE GAS DE Propano LíquidoManguera Y Regulador Conexión DE LA Manguera Y Regulador Verificación DE Ausencia DE Fugas Pruebas DE Detección DE FugasCuándo Realizar UNA Prueba DE Detección DE Fugas Lista DE Verificación Preliminar AL Encendido Encendido DE LAS Hornillas Principales CON UN Cerillo Instrucciones DE EncendidoEncendido DE LAS Hornillas Principales Encendido DE LA Hornilla Lateral Encendido DE LA Hornilla DEL Asador Estilo RotisserieApagado DE LA Parrilla Encendido DE LA Hornilla Lateral CON UN CerilloControl DE LAS Llamaradas Operación DE LA ParrillaPreparación DE LA Parrilla Para Usarla POR Primera VEZ Precalentamiento DE LA ParrillaLA Hornilla Lateral Cocción Estilo RotisserieRecomendaciones Útiles LimpiezaCocinar a LA Parrilla a LA Temperatura Apropiada INSTALACIÓN/MANTENIMIENTO DE LAS Hornillas Limpieza Y MantenimientoAntes DE Guardar LA Parrilla Rejillas Para CocinarPlacas DE Distribución DEL Calor Transporte Y AlmacenajeIdentificación Y Corrección DE Problemas Preguntas Frecuentes Preguntas Frecuentes Contenido DE LA Bolsa DE Partes Instrucciones DE Armado SI Faltan PARTES, Llame a Servicio AL Cliente AL Paso Paso Paso ProSeries 7741 Armada Warranty