Trane WPHF, WPVJ manual Dimensions/Weights/ Clearance, Improper Unit Lift

Page 6

Dimensions/Weights/ Clearance

Table 1: Unit weights

 

Shipping

Shipping

Size

Weight

Weight

 

with pallet (lb)

w/o pallet (lb)

 

WPVJ

 

 

 

 

018

249

239

024

250

240

 

 

 

030

298

288

036

315

305

 

 

 

042

324

314

048

398

388

 

 

 

060

439

429

072

440

430

 

 

 

 

WPHF

 

021, 027

279

267

 

 

 

035. 040

367

356

047, 057

433

403

 

 

 

WARNING

Improper Unit Lift!

Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in death or serious injury or possible equipment or property-only damage.

Unit Location and Clearances Locate the unit in an indoor area. The

ambient temperature surrounding the unit must not be less than 45°F. Do not locate the unit in areas subject to freezing.

Attention should be given to service clearance and technician safety. The unit should be easily maintained or serviced in all applications. There must be enough space for service per- sonnel to perform maintenance or re- pair. Provide sufficient room to make

Figure 1: Mechanical clearances - WPHFwater, and electrical connection(s). Lo- cal and national codes should be fol-

lowed in providing electrical power connections. See Figure 1 and 2 for mechanical clearances.

Figure 2: Mechanical clearances - WPVJ

6

WSHP-SVX04A-EN

Image 6
Contents Installation Owner Diagnostics Later Design SequenceResponsible Refrigerant Practices Contents Pre-installation Checklist Fiberglass WoolMicrobial Growth General Information Dimensions/Weights/ Clearance Improper Unit LiftDimensions Wpvj 018-024 LH Wpvj 018-024 RH Wpvj 030-042 LH Wpvj 030-042 RH Wpvj 048-072 LH Wpvj 048-072 RH Low Voltage Wiring AC & DC Requirements InstallationGeneral Installation Checks Filter InstallationUnit Installation Wpvj Water ConnectionUnit Installation Wphf Connecting a Distributed Pump Kit to a Closed Loop System Using AntifreezeCleaning and Flushing Water Loop Field Installed Power Wiring Control Power TransformerInstallation Low Voltage Wiring Thermostat LocationElectrical Requirements Ampacity DeviceRLA FLA RLA CSA Case WPHF057 Pre-Start Checklist Pre-Start-up ChecklistSequence Operation Operating Pressures WpvjOperating Pressure Water Pressure Drop Water VolumeStart-up Checklist and Log Flow ChecksStart-up Checklist Log Job Name Model Number Date Serial NumberMaintenance Preventive MaintenanceHazardous Chemicals Warranty Information Warranty Information Standard WarrantyGeneral Operation TroubleshootingHazardous Service Procedures Operation with a Conventional ThermostatTroubleshooting Checklist Unit short cyclesUnit Wiring Wpvj Basic 24V Diagram Unit Wiring Wpvj Tracer ZN510 Diagram Unit Wiring Wphf Basic 24V Diagram Unit Wiring Wphf Tracer ZN510 Diagram Trane