Brinkmann 810.63450 owner manual PRE-STARTCHECK List, PRE-START Check List

Page 10

6.Check each place listed (A-K) for growing bubbles which indicates a leak.

7.Turn off gas supply at cylinder valve.

8.Turn on control knobs to release gas pressure in hose.

9.Turn control knobs to "OFF" position.

10.Tighten any leaking connections.

11.Repeat soapy water test until no leaks are detected.

12.Turn off gas supply at cylinder valve until you are ready to use your grill.

13.Wash off soapy residue with cold water and towel dry.

14.Wait 5 minutes to allow all gas to evacuate the area before lighting grill.

,_ CAUTION!

DO NOT use

the grill if leaks

cannot be stopped.

Contact a qualified gas appliance

 

repair service.

 

 

 

 

 

 

 

NOTE:

The leak test

must be

performed

in an

area that

has adequate

lighting in order to see if

 

bubbles are developing.

DO

NOT

use

a flashlight to check for

bubbles.

PRE-STARTCHECK LIST:

Property damage, bodily harm, severe burns, and death could result from failure to follow these safety steps.These steps should be performed after the grill has been assembled and prior to each use. DO NOT operate this grill until you have read and understand ALL of the warnings and instructions in this manual.

PRE-START CHECK LIST:

Ensure that the grill is properly assembled.

Inspect the gas supply hose for burns, chaffing, kinks, and proper routing before each use. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior the grill being

used. Replace with hose and regulator, Model No. 155-2400-0, which can be obtained by contacting customer service at 800-527-0717.

Leak check all gas connections and hose. See section on "Leak Testing".

Ensure that all electrical supply cords are properly grounded. Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Hose should be at least 3 inches from hot surfaces.

Position your grill on level ground in a well ventilated location, a safe distance from combustible materials, buildings and overhangs.

Properly place the empty grease tray under the grease drain hole in the bottom of the grill to catch grease during use.

DO NOT obstruct the flow of combustion and ventilation air.

9

Image 10
Contents Grand Gourmet Important Safety Contents General Warnings Installation Information LP GAS Cylinder not Supplied with this GrillCylinder Specifications Regulator Resetting Procedure Installing the LP GAS Cylinder Onto the GrillFilling the LP GAS Cylinder Connecting Hose and Regulator to AN LP GAS Cylinder Connecting Hose and RegulatorWhen to Perform a Leaktest Leak TestingChecking for Leaks PRE-STARTCHECK List PRE-START Check ListLighting the Main Burners Lighting InstructionsMatch Lighting the Main Burners Match Lighting the Side Burner Lighting the Side BurnerTurning OFF the Grill Preheating the Grill Operating the GrillBreaking in Your Grill Controlling FLARE-UPSRotisserie Cooking Side BurnerGrilling to Proper Temperature CleanlinessHelpful Hints Cleaning and Maintenance Burner ASSEMBLY/MAINTENANCETransporting and Storage Heat Distribution PlatesBefore Storing Your Grill Trouble Shooting Problem Possible CausesFrequently Asked Questions Frequently Asked Questions Parts BAG Contents Assembly Instructions For Missing PARTS, Please Call Customer Service AT Page Step Step Grease Cup Heat Plate CZ222222 C2222 Side Front Panel Side Table Side Burner Step Step @,÷....s@=iiii ProSeries 6345 Assembled Accessories Gallon PAN & Basket SET 140-6345-0 10/05 810-6345-0