REMOTE CONTROLLER (CONTINUED)

MODE selector button

Use this button to select AUTO, HEAT, DRY or COOL mode.

 

(AUTO)

 

: The air conditioner calculates the difference between the thermostat

 

 

 

 

setting and room temperature, and automatically selects ‘‘COOL’’ or

 

 

 

 

‘‘HEAT’’ mode as appropriate.

 

(HEAT)

 

: The air conditioner makes the room warmer.

 

(DRY)

 

: The air conditioner reduces the humidity in the room.

(COOL)

 

: The air conditioner makes the room cooler.

 

 

 

When multiple indoor units are used and units in other rooms are already operating, they

 

NOTE

 

 

 

 

will be set to the same mode of operation as the operating indoor units.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN SPEED selector button

 

: The air conditioner automatically decides the fan speeds.

 

 

 

 

: High fan speed

 

 

 

 

: Medium fan speed

 

 

 

 

: Low fan speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NIGHT SETBACK button

For details, see “4. Night Setback Mode”. When you press this button in the

 

 

 

HEAT, DRY or COOL mode, the mark appears in the display, and the remote

 

 

 

controller will automatically adjust the set temperature to save energy.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLAP button

Press this button either to select the setting of the airflow direction to the auto.

 

 

 

flap in each mode or one of the six possible positions manually or to select the

 

 

 

sweep function which moves the flap up and down automatically.

 

 

 

 

: Auto flap setting: If selected in a heating operation, the flap is set to

 

 

 

 

position (3) in the following chart. If selected in a cooling or dry operation,

 

 

 

 

the flap is set at position (7) in the following chart.

 

 

 

 

: The airflow direction can be set manually. (six positions)

 

 

 

 

: The flap moves up and down automatically.

 

 

 

When you press the FLAP button, the air flow direction will be changed one by

 

NOTE

 

 

 

 

one as follows.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWEEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH POWER button

 

: If this button is pressed during HEAT, DRY or COOL operation, the unit

 

 

 

 

operates at maximum output for 30 minutes, regardless of the desired

 

 

 

 

temperature.

 

 

 

 

The fan speed is 1 step above “High”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON TIME/OFF TIME setting

No display: The timer does not operate.

buttons

 

: The air conditioner starts at the set time.

 

 

 

 

: The air conditioner stops at the set time.

 

 

 

 

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

 

 

 

 

set times every day. For details, see “SETTING THE TIMER”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR button

When you press this button (use a small-tipped object such as a ballpoint pen),

 

 

 

the

mark will appear at the display. And the room temperature is detected by

 

 

 

the sensor which is built into the indoor unit and the air conditioner is controlled

 

 

 

accordingly.

 

 

If the remote controller is located near a heat source, such as a space heater or in

 

NOTE

 

 

 

 

direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.

9

Image 10
Contents CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Model No Indoor Units Outdoor UnitsSafety Precautions FeaturesContents Product InformationSafety Instructions Installation LocationElectrical Requirements Page Names of Parts Unit Display and Operation Button Quiet lampRemote Controller Display Advance button Remote ControllerTemperature setting buttons TransmitterRemote Controller On TIME/OFF Time settingHow to Install Batteries Using the Remote ControllerTemperature Display Selector Button Time Display Selector buttonRear Side Hole Air Conditioner Indoor unit Receiver Remote ControllerTo take out the remote controller, pull it forward ControllerAutomatic Operation Operation with the Remote ControllerPress the ON/OFF operation button Operation with the Remote Controller Manual OperationAdjusting the Fan Speed Night Setback Mode is used for saving energy Night Setback ModeCooling and DRY Mode Heating Mode Quiet Mode High Power ModeHeating Remote ControllerSpecial Remarks Clicking SoundHow to set the present time Setting the TimerOperation Indication To cancel a timer program Press the Cancel button Repeat timer1030 pm 710 am 1100 am Present time Cancellation procedure Using the 1-HOUR OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction HorizontalCare and Cleaning Operation Without the Remote ControllerWhen the air conditioner is not running How to remove the filter 1. Grasp both ends of the air Groove Pin Air intake grilleWired Remote Controller Removing and remounting the air intake grilleOperating Range Troubleshooting Before Calling for ServiceTrouble Possible Cause Remedy Specifications CS-MKE7NKU CS-MKE9NKU CS-MKE12NKUPage CS-MKE18NKU CS-MKE24NKU CS-MKE24NKU Model No Indoor Units Outdoor UnitsAuto/High/Medium/Low Installation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Selector button Remote Controller Using the Remote Controller Rear Side Remote Control Holder Hole Mounting Screws 5/32 x 5/8 4 x 16 mm IncludedOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU
Related manuals
Manual 122 pages 9.57 Kb Manual 124 pages 42.9 Kb Manual 114 pages 38.6 Kb

CS-MKE12NKU, CU-3KE19NBU, CU-4KE24NBU, CU-4KE31NBU, CS-MKE7NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.