If you have lost the remote controller or it has trouble, follow the steps below.

When the air conditioner is not running

Each time the OPERATION button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation.

Cooling operation

 

Heating operation

 

Stop

 

 

(green)

 

(red)

 

(lamp off)

OPERATION button

NOTE

The temperature is set to the room temperature minus 4 °F during the cooling operation and to the room temperature plus 4 °F during the heating operation, and the fan speed and flap are set to Auto.

CARE AND CLEANING

1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

2.Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.

Casing and Grille (Indoor Unit) Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth.

If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the grille, be careful not to force the vanes out of place.

CAUTION

1.Never use solvents, or harsh chemicals when cleaning the indoor unit. Do not wipe the plastic casing using very hot water.

2.Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.

3.The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center.

22

Image 51
Contents CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Outdoor Units Model No Indoor UnitsProduct Information FeaturesContents Safety PrecautionsInstallation Location Safety InstructionsElectrical Requirements Page Names of Parts Quiet lamp Unit Display and Operation ButtonRemote Controller Display Transmitter Remote ControllerTemperature setting buttons Advance buttonOn TIME/OFF Time setting Remote ControllerButton Time Display Selector button Using the Remote ControllerTemperature Display Selector How to Install BatteriesController Air Conditioner Indoor unit Receiver Remote ControllerTo take out the remote controller, pull it forward Rear Side HoleOperation with the Remote Controller Automatic OperationPress the ON/OFF operation button Manual Operation Operation with the Remote ControllerAdjusting the Fan Speed Night Setback Mode Night Setback Mode is used for saving energyCooling and DRY Mode Heating Mode High Power Mode Quiet ModeClicking Sound Remote ControllerSpecial Remarks HeatingSetting the Timer How to set the present timeOperation Indication Repeat timer To cancel a timer program Press the Cancel button1030 pm 710 am 1100 am Present time Operation together with the Daily ON/OFF Repeat Timer Using the 1-HOUR OFF TimerSetting procedure Cancellation procedureHorizontal Adjusting the Airflow DirectionOperation Without the Remote Controller Care and CleaningWhen the air conditioner is not running Groove Pin Air intake grille How to remove the filter 1. Grasp both ends of the airRemoving and remounting the air intake grille Wired Remote ControllerTroubleshooting Before Calling for Service Operating RangeTrouble Possible Cause Remedy CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU SpecificationsPage CS-MKE18NKU CS-MKE24NKU Model No Indoor Units Outdoor Units CS-MKE24NKUAuto/High/Medium/Low Installation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Selector button Remote Controller Using the Remote Controller Hole Mounting Screws 5/32 x 5/8 4 x 16 mm Included Rear Side Remote Control HolderOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU
Related manuals
Manual 122 pages 9.57 Kb Manual 124 pages 42.9 Kb Manual 114 pages 38.6 Kb

CS-MKE12NKU, CU-3KE19NBU, CU-4KE24NBU, CU-4KE31NBU, CS-MKE7NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.