We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

Do not install this air conditioner where there are fumes or flammable

gases, or in an extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heat- generating objects are placed.

Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

NOTE

ELECTRICAL REQUIREMENTS

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.

SAFETY INSTRUCTIONS

Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

Confirm to authorized dealer or specialist on usage of specified refrigerant type.

Using of refrigerant other than the specified type may cause product damage, burst and injury etc.

Never touch the unit with wet hands.

Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

Do not use this appliance in a potentially explosive atmosphere.

This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

Do not swallow the battery.

After removing the battery from remote controller, keep it away from the reach of children. The battery can cause death by suffocation if swallowed.

When inserting the battery, make sure the polarities (+ and -) are correct.

3

Image 32
Contents CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Model No Indoor Units Outdoor UnitsFeatures ContentsSafety Precautions Product InformationElectrical Requirements Installation LocationSafety Instructions Page Names of Parts Unit Display and Operation Button Quiet lampRemote Controller Display Remote Controller Temperature setting buttonsAdvance button TransmitterRemote Controller On TIME/OFF Time settingUsing the Remote Controller Temperature Display SelectorHow to Install Batteries Button Time Display Selector buttonAir Conditioner Indoor unit Receiver Remote Controller To take out the remote controller, pull it forwardRear Side Hole ControllerPress the ON/OFF operation button Operation with the Remote ControllerAutomatic Operation Operation with the Remote Controller Manual OperationAdjusting the Fan Speed Cooling and DRY Mode Heating Mode Night Setback ModeNight Setback Mode is used for saving energy Quiet Mode High Power ModeRemote Controller Special RemarksHeating Clicking SoundOperation Indication Setting the TimerHow to set the present time 1030 pm 710 am 1100 am Present time Repeat timerTo cancel a timer program Press the Cancel button Using the 1-HOUR OFF Timer Setting procedureCancellation procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction HorizontalWhen the air conditioner is not running Operation Without the Remote ControllerCare and Cleaning How to remove the filter 1. Grasp both ends of the air Groove Pin Air intake grilleWired Remote Controller Removing and remounting the air intake grilleTrouble Possible Cause Remedy Troubleshooting Before Calling for ServiceOperating Range Specifications CS-MKE7NKU CS-MKE9NKU CS-MKE12NKUPage CS-MKE18NKU CS-MKE24NKU CS-MKE24NKU Model No Indoor Units Outdoor UnitsAuto/High/Medium/Low Installation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Selector button Remote Controller Using the Remote Controller Rear Side Remote Control Holder Hole Mounting Screws 5/32 x 5/8 4 x 16 mm IncludedOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU
Related manuals
Manual 122 pages 9.57 Kb Manual 124 pages 42.9 Kb Manual 114 pages 38.6 Kb

CS-MKE12NKU, CU-3KE19NBU, CU-4KE24NBU, CU-4KE31NBU, CS-MKE7NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.