Panasonic CU-4KE31NBU, CS-MKE9NKU, CS-MKE7NKU, CU-4KE24NBU appendix Adjusting the Airflow Direction

Page 50

ADJUSTING THE AIRFLOW DIRECTION

1. Horizontal

CAUTION

The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right.

When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down.

2.Vertical The vertical airflow can be adjusted by moving the flap with the remote controller. Do not move the flap with your hands. Confirm that the remote controller has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

 

SWEEP

 

 

COOL

 

 

DRY

SWEEP

 

 

 

 

HEAT

A. Sweep function

B. Setting the airflow manually

 

The flap starts moving up and down to

 

Referring to the above illustration, use the

deliver air over the sweep range.

FLAP button to set the airflow direction

 

C. Auto flap function

within the range used during the heating,

cooling, or dehumidifying operation.

The flap is set to the recommended

 

 

position.

 

 

NOTE

CAUTION

The flap automatically closes when the unit is off.

During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position ) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote controller.

Use the FLAP button on the remote controller to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote controller and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.

Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

21

Image 50
Contents CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Model No Indoor Units Outdoor UnitsSafety Precautions FeaturesContents Product InformationElectrical Requirements Installation LocationSafety Instructions Page Names of Parts Unit Display and Operation Button Quiet lampRemote Controller Display Advance button Remote ControllerTemperature setting buttons TransmitterRemote Controller On TIME/OFF Time settingHow to Install Batteries Using the Remote ControllerTemperature Display Selector Button Time Display Selector buttonRear Side Hole Air Conditioner Indoor unit Receiver Remote ControllerTo take out the remote controller, pull it forward ControllerPress the ON/OFF operation button Operation with the Remote ControllerAutomatic Operation Operation with the Remote Controller Manual OperationAdjusting the Fan Speed Cooling and DRY Mode Heating Mode Night Setback ModeNight Setback Mode is used for saving energy Quiet Mode High Power ModeHeating Remote ControllerSpecial Remarks Clicking SoundOperation Indication Setting the TimerHow to set the present time 1030 pm 710 am 1100 am Present time Repeat timerTo cancel a timer program Press the Cancel button Cancellation procedure Using the 1-HOUR OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction HorizontalWhen the air conditioner is not running Operation Without the Remote ControllerCare and Cleaning How to remove the filter 1. Grasp both ends of the air Groove Pin Air intake grilleWired Remote Controller Removing and remounting the air intake grilleTrouble Possible Cause Remedy Troubleshooting Before Calling for ServiceOperating Range Specifications CS-MKE7NKU CS-MKE9NKU CS-MKE12NKUPage CS-MKE18NKU CS-MKE24NKU CS-MKE24NKU Model No Indoor Units Outdoor UnitsAuto/High/Medium/Low Installation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Selector button Remote Controller Using the Remote Controller Rear Side Remote Control Holder Hole Mounting Screws 5/32 x 5/8 4 x 16 mm IncludedOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU
Related manuals
Manual 122 pages 9.57 Kb Manual 124 pages 42.9 Kb Manual 114 pages 38.6 Kb

CS-MKE12NKU, CU-3KE19NBU, CU-4KE24NBU, CU-4KE31NBU, CS-MKE7NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.