IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

When Transporting

Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin alu- minum fins on the air conditioner can cut your fingers.

When Installing…

Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

WARNING

CAUTION

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result in personal injury or prod- uct or property damage.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

 

Keep the fire alarm and the air

 

CAUTION

outlet at least 1.5 m away from

the unit.

 

 

 

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improp- er installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

‡'RQRWVXSSO\SRZHUWRWKHXQLWXQWLODOOZLULQJDQGWXELQJ are completed or reconnected and checked.

‡+LJKO\GDQJHURXVHOHFWULFDOYROWDJHVDUHXVHGLQWKLV system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

‡*URXQGWKHXQLW following local electrical codes.

‡&RQQHFWDOOZLULQJWLJKWO\/RRVHZLULQJPD\FDXVHRYHU heating at connection points and a possible fire hazard.

‡7RSUHYHQWSRVVLEOHKD]DUGVIURPLQVXODWLRQIDLOXUH

the unit must be grounded.

When Connecting Refrigerant Tubing

‡ :KHQSHUIRUPLQJpiping work

 

do not mix air except for speci-

 

fied refrigerant (R410A) in

 

refrigeration cycle. It causes

 

capacity down, and risk of

 

explosion and injury due to

 

high tension inside the refrige-

WARNING

rant cycle.

‡ 5HIULJHUDQWJDVOHDNDJHPD\

 

 

cause fire.

‡'RQRWDGGRUUHSODFHUHIULJHUDQW other than specified type.

It may cause product damage, burst and injury etc.

‡9HQWLODWHWKHURRPZHOOLQWKHHYHQWWKDWUHIULJHUDQW gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.

‡'RQRWDGGDQ\UHIULJHUDQWDLURUVXEVWDQFHLQWRWKH refrigeration circuit other than the designated refrigerant (R410A). Adding anything other than the specified refrig- erant may cause the pressure to rise excessively in the refrigeration circuit, rupturing the circuit and causing injury or damage.

‡8VHDOOQHZWXELQJDQGIODUHQXWVWRPDNHWKHWXELQJFRQ nections. Using any previous parts (from R22-based sys- tems) may result in damage to the equipment, and may lead to the refrigeration circuit rupturing, causing a seri- ous accident.

2

Image 102
Contents DC Inverter MULTI-SYSTEM AIR Conditioner Safety Precautions Prohibit Table of Contents Applicable MULTI-OUTDOOR Units Operating Range Unit Specifications Indoor UnitCS-MKE7NKU 208V CS-MKE9NKU CS-MKE9NKU CS-MKE12NKU CS-MKE12NKU CS-MKE18NKU CS-MKE18NKU CS-MKE24NKU CS-MKE24NKU Major Component Specifications Indoor UnitIndoor Unit CS-MKE7NKU Indoor Unit CS-MKE9NKU CB-CS-MKE9NKUIndoor Unit CS-MKE12NKU CB-CS-MKE12NKUIndoor Unit CS-MKE18NKU CB-CS-MKE18NKUIndoor Unit CS-MKE24NKU CB-CS-MKE24NKUOther Component Specifications Temperature F CDimensional Data CS-MKE9NKU CS-MKE12NKUCS-MKE24NKU Refrigerant Flow Diagram Indoor unitAir Throw Distance Charts Performance DataCooling CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU Electric Wiring Diagrams CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU8FA2-5251-11000-2 Emergency operation Auto Initial Operation Mode SelectionOperation Functions PAM- controlTimer backup Lamp colorsFreeze prevention Protective FunctionsOverload prevention during heating Cold-air prevention during heatingPrecautions before Performing Inspection or Repair Method of Self-DiagnosticsSelf-diagnostics Lamps Code Diagnosis ContentsNormal Replace the controllerReplace the circuit board or the fuse Using the TEST/T-RUN terminals Checking the Indoor and Outdoor UnitsChecking the indoor unit Control Check items unit operation How to Identify a Serial Communication Error Condition E12 Trouble Diagnosis of Fan Motor Indoor Fan MotorNoise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Page CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Operating Instructions Split System Air Conditioner Safety Precautions FeaturesContents Product InformationInstallation Location Safety InstructionsElectrical Requirements Page Names of Parts Indoor UnitOutdoor Unit Unit Display and Operation Button Heat red, DRY orange and Cool green modeThis lamp lights during operation in the Quiet mode DefrostingRemote Controller Display On Time Remote ControllerHour OFF Timer OFF TimeHeat On TIME/OFF Time settingAuto DRYHow to Install Batteries Using the Remote ControllerTemperature Display Selector Button Time Display Selector buttonReceiver which could block the signal Air Conditioner Indoor unit Receiver Remote ControllerTo take out the remote controller, pull it forward Rear Side HoleOperation with the Remote Controller StepPress the ON/OFF operation button Set the FAN Speed selector button to the setting you want Press the Mode selector button and select the desired modePress the TEMP. setting buttons to change the temperature Refer to Adjusting the Airflow Direction onAdjusting the Fan Speed Night Setback Mode is used for saving energy Cooling and DRY Mode Heating ModeQuiet Mode Special Remarks Setting the Timer Example To set to 1030 pmOperation Indication 1030 pm 710 am 1100 am Present time How to set the on time Example To start operation at 710 amTo cancel a timer program Press the Cancel button OFFCancellation procedure Using the 1-HOUR OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction HorizontalSweep Cool DRY Heat Operation Without the Remote Controller Care and CleaningWhen the air conditioner is not running How to remove the filter 1. Grasp both ends of the air Groove Pin Air intake grillePress in the bottom right Wired Remote Controller Removing and remounting the air intake grilleTrouble Possible Cause Remedy Troubleshooting Before Calling for ServiceOperating Range Max DB / 71 F WB Min DB / 57 F WBSpecifications CS-MKE7NKU CS-MKE9NKU CS-MKE12NKUPage CS-MKE18NKU CS-MKE24NKU CS-MKE18NKU Automatic Restart Function for Power Failure Auto/High/Medium/LowInstallation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Selector button Press Button to reduce the set temperatureSetting changes by 1 C or 2 F each time one of the Temp OpenedRemote Controller Using the Remote Controller Rear Side Remote Control Holder Hole Mounting Screws 5/32 x 5/8 4 x 16 mm IncludedOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU Page 852-6-4190-583-00-0 Contents For Indoor Unit…In a Ceiling or Wall For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a RoomWhen Servicing General Installation Site Selection Additional Materials Required for InstallationAvoid Embedding the Tubing and Wiring Remove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleInstall the Rear Panel on the Wall If Wooden WallIf Block, Brick, Concrete or Similar Type Wall Removing and Installing the Grille Indoor unit types How to replace the grilleCS-MKE7NKU, CS-MKE9NKU, CS-MKE12NKU Indoor unit types CS-MKE18NKU, CS-MKE24NKU Wiring Instructions General precautions on wiring Shape the Indoor Side TubingWiring Instructions for Inter-unit Connections How to connect wiring to the terminal For Indoor Unit For Outdoor Unit  For solid core wiring or F-cable For stranded wiring Mounting  Right-side tubing Left-side tubing Switch the drain hose and drain capSwitching drain hose and drain cap Drain capTo unmount indoor unit Do not supply power toTubing and wiring to the out Unit or operate it until allHow to Test Run the Air Conditioner Remote Controller Installation Position Mounting on a WallAddress Switch Address Setting of the Remote ControllerConnecting a Home Automation Device Installation Check SheetPage DC1111-0
Related manuals
Manual 56 pages 332 b

CS-MKE24NKU, CS-MKE12NKU, CS-MKE18NKU, CS-MKE7NKU, CS-MKE9NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.