Panasonic CS-MKE9NKU  Left-side tubing, Switch the drain hose and drain cap, Drain cap

Page 115

Left-side tubing

 /HDGWKHWXELQJDQGGUDLQKRVHWKURXJKWKHZDOO allowing sufficient length for connection. Then bend the tubing using a tube bender to make the attach- ment. (Fig. 38)

(2)Switch the drain hose and drain cap.

Switching drain hose and drain cap

D /RFDWHWKHGUDLQKRVHDQGWKHGUDLQFDS )LJ

39)

(b)Remove the screw fastening the drain hose on the right side, and pull out the drain hose to remove it. (Fig. 39)

(c)Apply moderate force to pull off the drain cap on the left side. (If you cannot pull it off by hand, use a long-nose pliers.)

(d)Reattach the drain hose to the left side and the drain cap to the right side. (Fig. 40a)

Drain hose

Slide the drain hose fully onto the drain pan outlet until the drain hose edge is pushed into the insula- tion. Check that the screw holes in the drain bracket and the drain pan outlet are aligned and securely in contact, then fasten them with the screw. (After attaching the drain hose, check that it is attached securely.) (Fig. 40c)

Drain cap

Use a Phillips screwdriver to push the drain cap in firmly. (If it is difficult to push in, wet the cap with water first.)

(3)Install the indoor unit on the rear panel.

(4)Connect the tubing and wiring led inside from out- doors.

(5)After completing a leak test, bundle the tubing together with armoring tape and store it inside the tubing storage area at the back of the indoor unit and hold it with clamps. (Figs. 40a and 41)

Rear panel

Hole in wall

Bent part

Wide tube

 

Narrow tube

Fig. 38

Drain cap

Drain hose

Fig. 39

Drain hose

Clamp

Drain cap

Fig. 40a

Screw hole

Drain pan outlet

Insulation

 

 

Drain bracket

Drain bracket

 

 

Drain hose

 

 

Drain hose

Screw

 

Fig. 40c

 

Fig. 40b

 

 

Refrigerant tubing

 

 

Inter-unit wiring

 

Conduit

 

Fig. 41

15

Image 115
Contents DC Inverter MULTI-SYSTEM AIR Conditioner Safety Precautions Prohibit Table of Contents Applicable MULTI-OUTDOOR Units Operating Range Indoor Unit Unit SpecificationsCS-MKE7NKU 208V CS-MKE9NKU CS-MKE9NKU CS-MKE12NKU CS-MKE12NKU CS-MKE18NKU CS-MKE18NKU CS-MKE24NKU CS-MKE24NKU Indoor Unit Major Component SpecificationsIndoor Unit CS-MKE7NKU CB-CS-MKE9NKU Indoor Unit CS-MKE9NKUCB-CS-MKE12NKU Indoor Unit CS-MKE12NKUCB-CS-MKE18NKU Indoor Unit CS-MKE18NKUCB-CS-MKE24NKU Indoor Unit CS-MKE24NKUTemperature F C Other Component SpecificationsCS-MKE9NKU CS-MKE12NKU Dimensional DataCS-MKE24NKU Indoor unit Refrigerant Flow DiagramPerformance Data Air Throw Distance ChartsCooling CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU Electric Wiring Diagrams8FA2-5251-11000-2 PAM- control Auto Initial Operation Mode SelectionOperation Functions Emergency operationLamp colors Timer backupCold-air prevention during heating Protective FunctionsOverload prevention during heating Freeze preventionMethod of Self-Diagnostics Precautions before Performing Inspection or RepairCode Diagnosis Contents Self-diagnostics LampsReplace the controller NormalReplace the circuit board or the fuse Checking the Indoor and Outdoor Units Using the TEST/T-RUN terminalsChecking the indoor unit Control Check items unit operation How to Identify a Serial Communication Error Condition E12 Indoor Fan Motor Trouble Diagnosis of Fan MotorNoise malfunction Noise Malfunction and Electromagnetic InterferenceElectromagnetic interference Page CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU Operating Instructions Split System Air Conditioner Product Information FeaturesContents Safety PrecautionsSafety Instructions Installation LocationElectrical Requirements Page Indoor Unit Names of PartsOutdoor Unit Defrosting Heat red, DRY orange and Cool green modeThis lamp lights during operation in the Quiet mode Unit Display and Operation ButtonRemote Controller Display OFF Time Remote ControllerHour OFF Timer On TimeDRY On TIME/OFF Time settingAuto HeatButton Time Display Selector button Using the Remote ControllerTemperature Display Selector How to Install BatteriesRear Side Hole Air Conditioner Indoor unit Receiver Remote ControllerTo take out the remote controller, pull it forward Receiver which could block the signalStep Operation with the Remote ControllerPress the ON/OFF operation button Refer to Adjusting the Airflow Direction on Press the Mode selector button and select the desired modePress the TEMP. setting buttons to change the temperature Set the FAN Speed selector button to the setting you wantAdjusting the Fan Speed Cooling and DRY Mode Heating Mode Night Setback Mode is used for saving energyQuiet Mode Special Remarks Example To set to 1030 pm Setting the TimerOperation Indication OFF How to set the on time Example To start operation at 710 amTo cancel a timer program Press the Cancel button 1030 pm 710 am 1100 am Present timeOperation together with the Daily ON/OFF Repeat Timer Using the 1-HOUR OFF TimerSetting procedure Cancellation procedureHorizontal Adjusting the Airflow DirectionSweep Cool DRY Heat Care and Cleaning Operation Without the Remote ControllerWhen the air conditioner is not running Groove Pin Air intake grille How to remove the filter 1. Grasp both ends of the airPress in the bottom right Removing and remounting the air intake grille Wired Remote ControllerMax DB / 71 F WB Min DB / 57 F WB Troubleshooting Before Calling for ServiceOperating Range Trouble Possible Cause RemedyCS-MKE7NKU CS-MKE9NKU CS-MKE12NKU SpecificationsPage CS-MKE18NKU CS-MKE24NKU CS-MKE18NKU Auto/High/Medium/Low Automatic Restart Function for Power FailureInstallation Location Page Names of Parts Unit Display and Operation Button Hour clock with ON/OFF program Timer Opened Press Button to reduce the set temperatureSetting changes by 1 C or 2 F each time one of the Temp Selector buttonRemote Controller Using the Remote Controller Hole Mounting Screws 5/32 x 5/8 4 x 16 mm Included Rear Side Remote Control HolderOperation with the Remote Controller Operation with the Remote Controller Adjusting the Fan Speed Cooling and DRY Mode Quiet Mode Special Remarks Setting the Timer Setting the Timer Using the 1-HOUR OFF Timer Adjusting the Airflow Direction Operation Without the Remote Controller Rear of the air intake grille Wired Remote Controller Troubleshooting Before Calling for Service CS-MKE18NKU CS-MKE24NKU Page 852-6-4190-583-00-0 For Indoor Unit Contents…In a Room For safe installation and trouble-free operation, you mustPlease Read Before Starting …In a Ceiling or WallWhen Servicing General Additional Materials Required for Installation Installation Site SelectionAvoid Embedding the Tubing and Wiring Make a Hole How to Install the Indoor UnitTrical wiring or conduits are Remove the Rear Panel from the UnitIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall How to replace the grille Removing and Installing the Grille Indoor unit typesCS-MKE7NKU, CS-MKE9NKU, CS-MKE12NKU Indoor unit types CS-MKE18NKU, CS-MKE24NKU Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringWiring Instructions for Inter-unit Connections For Outdoor Unit  For solid core wiring or F-cable How to connect wiring to the terminal For Indoor Unit For stranded wiring  Right-side tubing MountingDrain cap Switch the drain hose and drain capSwitching drain hose and drain cap  Left-side tubingUnit or operate it until all Do not supply power toTubing and wiring to the out To unmount indoor unitHow to Test Run the Air Conditioner Mounting on a Wall Remote Controller Installation PositionAddress Setting of the Remote Controller Address SwitchInstallation Check Sheet Connecting a Home Automation DevicePage DC1111-0
Related manuals
Manual 56 pages 332 b

CS-MKE24NKU, CS-MKE12NKU, CS-MKE18NKU, CS-MKE7NKU, CS-MKE9NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.