19.During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).

20.During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of refrigeration piping while compressor is operating and valves are opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).

21.After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire.

22.Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.

23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.

24.Must not use other parts except original parts describe in catalog and manual.

25.Using of refrigerant other than the specified type may cause product damage, burst and injury etc.

CAUTION

1.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire.

2.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.

3.Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.

4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.

5.Select an installation location which is easy for maintenance.

6.Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).

Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).

7.Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods.

Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited.

i.Power supply connection to the receptacle using a power plug.

Use an approved 15/16A (1.0 ~ 1.75HP) or 16A (2.0HP) or 20A (2.5HP) power plug with earth pin for the connection to the socket.

ii.Power supply connection to a circuit breaker for the permanent connection.

Use an approved 16A (1.0 ~ 2.0HP) or 20A (2.5HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.

8.Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite.

9.Installation or servicing work: It may need two people to carry out the installation or servicing work.

10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.

11. Do not sit or step on the unit, you may fall down accidentally.

12.Do not touch the sharp aluminium fins or edges of metal parts.

If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury.

4

Image 4
Contents CS-E9NKUAW CU-E9NKUA CS-E12NKUAW CU-E12NKUA Exploded View and Replacement Parts List Safety Precautions Page Specification CU-E9NKUA CU-E12NKUA ARIType Propeller Fan Material Motor Type DC 8 poles DRY Bulb WET Bulb Features š Easy to use remote control š Quality ImprovementIndoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Outdoor Unit Electronic Circuit Diagram Outdoor Unit Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board Outdoor Unit Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wiring Stripping and connecting requirement Cutting and flaring the pipingInstall the Outdoor Unit Connect the PipingConnecting the piping to outdoor multi Evacuation of the equipmentConnect the Cable to the Outdoor Unit Operation Control Basic FunctionIndoor Fan Motor Operation Basic Rotation Speed rpmAirflow Direction Outdoor Fan Motor OperationVertical Airflow Quiet Operation Heating Quiet Operation Cooling Mode/Cooling Area of Dry ModeHorizontal Airflow Powerful Mode Operation Timer ControlOn Timer Control OFF Timer ControlIndication Panel Operation Control For Multi Split Connection Cooling operationSoft Dry Operation Heating OperationAutomatic Operation Residual Heat Removal ControlProtection Control Protection Control For All OperationsOutdoor Air Temperature Control Protection Control For Cooling & Soft Dry OperationCompressor Overheating Prevention Control Low Pressure Prevention Control Gas Leakage DetectionCooling Overload Control Freeze Prevention ControlDew Prevention Control Protection Control For Heating OperationOutdoor Air Temperature Control Servicing Mode Auto Off/On ButtonRemote Control Button Troubleshooting Guide Refrigeration Cycle SystemPage To Display Memorized Error Code Protective Operation Breakdown Self Diagnosis FunctionSelf Diagnosis Function Three Digits Alphanumeric Code To Make a DiagnosisError Code Table Page Self-diagnosis Method 16.4.1 H11 Indoor/Outdoor Abnormal Communication16.4.2 H12 Indoor/Outdoor Capacity Rank Mismatched 16.4.3 H14 Indoor Intake Air Temperature Sensor Abnormality 16.4.4 H15 Compressor Temperature Sensor Abnormality 16.4.5 H16 Outdoor Current Transformer Open Circuit 16.4.6 H19 Indoor Fan Motor DC Motor Mechanism Locked 16.4.7 H23 Indoor Pipe Temperature Sensor Abnormality 16.4.8 H27 Outdoor Air Temperature Sensor Abnormality 16.4.9 H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions Malfunction Decision Conditions 16.4.12 H33 Unspecified Voltage between Indoor and Outdoor 16.4.13 H36 Outdoor Gas Pipe Sensor Abnormality Malfunction Decision Conditions 16.4.15 H97 Outdoor Fan Motor DC Motor Mechanism Locked 16.4.16 H98 Indoor High Pressure Protection Malfunction Decision Conditions 16.4.18 F11 Indoor Pipe Temperature Sensor Abnormality 16.4.19 F17 Indoor Standby Units Freezing Abnormality Remark16.4.20 F90 Power Factor Correction Protection 16.4.21 F91 Refrigeration Cycle Abnormality 16.4.22 F93 Compressor Rotation Failure 16.4.23 F95 Cooling High Pressure Abnormality 16.4.24 F96 IPM Overheating 16.4.25 F97 Compressor Overheating 16.4.26 F98 Input Over Current Detection 16.4.27 F99 Output Over Current Detection Disassembly and Assembly Instructions To remove front grilleTo remove discharge grille Page Page Operation Characteristics Technical DataCS-E9NK CU-E9NK 139.500 139.000 Piping Length ft 600 Current 400 300 200 100 Page Page CS-E12NK CU-E12NK Page Page Page Exploded View and Replacement Parts List Chassis Complete Outdoor Unit Chassis Assy
Related manuals
Manual 12 pages 57.08 Kb

CS-E9NKUAW, CU-E9NKUA, CU-E12NKUA, CS-E12NKUAW specifications

Panasonic has established itself as a leader in the air conditioning market, offering a range of products that combine advanced technology with energy efficiency. The Panasonic models CS-E12NKUAW, CU-E12NKUA, CU-E9NKUA, CSU-2E18NBU, and CS-E9NKUAW exemplify this commitment to quality and innovation.

The CS-E12NKUAW and CS-E9NKUAW are split-type air conditioners designed for residential use. One of the standout features of these models is their energy-efficient inverter technology. This innovation allows the compressor to adjust its speed according to the cooling demand, leading to lower energy consumption and cost savings for homeowners. Additionally, these units operate quietly, ensuring a peaceful environment while effectively maintaining comfortable temperatures.

The CU-E12NKUA and CU-E9NKUA are the corresponding outdoor units that support the indoor models. These units are designed for durability and performance, using robust materials that withstand various weather conditions. Panasonic's outdoor units are equipped with a reliable cooling system that enhances the overall efficiency and longevity of the air conditioning system.

The CSU-2E18NBU model is perfect for larger spaces, handling greater loads while ensuring consistent cooling. This unit also leverages inverter technology for efficient operation. The CSU models often include advanced features such as a high-density filter that captures dust and allergens, promoting a healthier indoor environment.

All these units are designed with user-friendly interfaces, allowing for easy temperature control and adjustments. Many of the models also come with remote control options, enabling users to regulate their comfort from the convenience of their seat. Additionally, advanced air purifying technology enhances indoor air quality by eliminating harmful pollutants and odors.

Panasonic air conditioners are known for their environmentally friendly refrigerants, contributing to a reduced carbon footprint and compliance with international standards. These features reflect Panasonic's commitment to sustainability and innovation, making these models a leading choice for consumers looking to balance comfort, efficiency, and environmental responsibility.

In summary, Panasonic's CS-E12NKUAW, CU-E12NKUA, CU-E9NKUA, CSU-2E18NBU, and CS-E9NKUAW models represent some of the best in today's air conditioning market, with key features including energy efficiency, user-friendly controls, advanced air purification, and robust outdoor units designed for performance and reliability. These units provide an ideal solution for maintaining a comfortable home environment while being conscious of energy use and environmental impact.