hussman Q1-DC operation manual Maintenance, Evaporator Fans, Coils, Replacing Fluorescent Lamps

Page 10

Q1-DC-0508

Maintenance

FOR PROMPT SERVICEHave case Model and Serial Numberready!

This information is located on thenameplate of the unit.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heaters Thermostats, and Lights.

Evaporator Fans

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.

Coils

The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.

Hussmann recommends using #15 Sil-Fos for repairs.

Tips and Troubleshooting

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are open - allowing moisture to enter store.

Replacing Fluorescent Lamps

Fluorescent lamps are furnished with a shatterproof protective coating. The same type of lamp with protective coating must be used if replaced.

 

 

ENCAPSULITE

 

RU

SHATTERPROOF COATING - SA 10645

NSF

Complies with FDA USDA

R

 

 

 

& OSHA Regulations

 

 

 

for replacement call:

 

 

 

 

1-800-395-9229

 

 

 

 

Turn switch off then on after replacing bulb

 

 

 

 

 

 

CLEANING PRECAUTIONS

When cleaning:

Do not use high pressure water hoses

Do not introduce water faster than waste outlet can drain

NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL BASE (these will dissolve the butyl sealants) or an AMMONIA BASE (this will corrode the copper componets of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY

DO NOT USE ABRASIVES OR STEEL WOOL PADS AS THESE

WILL MAR THE FINISH

Glass Replacement and Adjustment Instructions

In order to replace or adjust the glass, the glass must be placed in the raised position. The underside of the clamp is exposed, revealing the tightening screws. By turning these screws counterclockwise 1/4 turn each, the glass will be loosened for either removal or adjustment.

Note: Do not overtighten the screws since damage may occur.

10

Image 10
Contents Deli Service Case RevTable of Contents General InstructionsInstallation Cut and Plan ViewsInstallation Contd Do not USE PermagumPlumbing RefrigerationRefrigeration Contd Electrical Electrical Contd Finishing TouchesCleaning Glass and Mirrors When cleaningCase Cleaning User Information ContdPlexiglass and Acrylic Care CleaningNon-Glare Glass Antistatic CoatingsEvaporator Fans MaintenanceGlass Replacement and Adjustment Instructions CoilsElectrical Wiring Diagrams Q1-DCLoading DiagramsWiring Q1 DeliDELIQ1 Wiring Diagrams ContdW1750002 Q1DC-6RLoading 115 W1750003Q1DELI L1 4.9 #.# L2 #.# #.# L3 #.# #.#L1 6.7 #.# L2 #.# #.# L3 #.# #.# W1750005Loading Contd W1750006W1750026 Be GroundedW1750007 Diagrams ContdQ1-DC-6R Wiring Diagrams Be Grounded115 L2 L3 W1750009115 V L1 6.1 L2 L3 DWG # W1750010 Wiring Q1-DC-XS/Q1-DS-XSQ1-DC-4S/Q1-DS-4S PRE-LIMINARY Project Title Q1-DC-XS/Q1-DS-XSQ1-DC-5S/Q1-DS-5S Subject toQ1-DC-6S/Q1-DS-6S 20392457 4W .29AQ1-DC-7S/Q1-DS-7S Subject to ChangeQ1-DC-8S/Q1-DS-8S Q1-DC-9S/Q1-DS-9S Q1-DC-10S/Q1-DS-10S M MQ1-DC-11S/Q1-DS-11S Tecumseh HGA9462ZXDXM 115VAC, 60HZL2 L3 Gfci W1750034-010Appendix B. Application Recommendations Refrigerated Appendix A. Temperature Guidelines RefrigeratedAppendices Open DisplayAppendices Contd Appendix D. Recommendations to User RefrigeratedAppendices Contd Service Record