hussman operation manual Q1-DC-9S/Q1-DS-9S, Pre-Liminary

Page 28

OPTIONAL

OPTIONAL

OPTIONAL

SENSOR

SENSOR

SENSOR

LIGHT CIRCUIT= 1.34A

OPTIONAL

FLOAT SWITCH

DUPLEX 125-01-6984

PLUG NEMA 5-15P

28

SENSOR

 

DANFOSS

 

COMTROL

SENSOR

90TB002G01

AKS-11/164

CPC

225-01-2028

225-01-3225

225-01-3260

 

 

 

 

OPTIONAL SCALE STAND

 

 

CIRCUIT #2

 

RJ-45 NETWORK JACK

 

LOADING

 

125-01-0200

 

 

120 V

 

125-01-0202

 

L1

15.0

 

 

 

L2

 

 

 

 

L3

 

 

 

GFCI

NOTE: CASE MUST

 

DUPLEX

 

125-01-3178

BE GROUNDED

W G BK

 

 

 

 

 

 

CIRCUI T#2

 

(TWO MAXIMUM)

 

~120 VAC - 1Ø -60 Hz

LIGHT SWITCH TIPPETTE

125-01-0311

CANOPY

LIGHT

F35T5-60" 125-03-1135 F35T5-60" 125-03-1135

FULHAM LH4-120-L

BALLAST 125-01-3267

LEDGE LIGHT

CANOPY

OPTIONAL

LIGHT

 

F35T5-60" 125-03-1135

F28T5-48" 125-03-1132 F28T5-48" 125-03-1132

WIRE

CAP OFF

BALLAST 125-01-3267 FULHAM LH4-120-L

 

 

 

 

BALLAST 125-01-3267 FULHAM LH4-120-L

 

 

 

 

 

 

 

 

 

 

 

 

LEDGE LIGHT (OPTIONAL)

F28T5-48" 125-03-1132

WIRE

CAP OFF

FULHAM LH4-120-L

BALLAST 125-01-3267

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

14

BUNDLE

 

 

G

 

#

 

 

 

#

PURPLE

WHITE

 

 

 

 

 

BLACK

LABELED

 

 

 

 

 

 

 

EVAP PAN

 

 

 

 

 

 

 

CIRCUIT

 

N

L1

FISHER™ EVAPOWAY™

~120 VAC - 60 Hz.

DM15WW1D (OPTIONAL)

MCA= 15.7A

1500W @ ~ 120 VAC

MOP= 20A

12.5A

 

 

 

 

 

 

 

125-01-0765

 

 

AIR SWEEP FANS COMAIR™ MX2B1-E1 (2)125-01-2012 15W, .18A

M M

EVAP

FAN MOTOR (3)0392457 .29A

M M M

SAFETY

SWITCH

DEFROST TIMER OMNI-STAT 120V - 50/60 Hz. 125-01-2303

 

 

 

OMNI STAT PN

 

 

 

952896-120VAC

POWER

PROD.

AIR

SUPPLY

115Vac

TEMP.

TEMP.

9

8

7 6

5 4 3 2 1

L1 N

***

Wiring Diagrams (Cont'd)

L

# 14

# 14

CIRCUIT #1

 

BLACK # 14

#14

BUNDLE

SWITCH

#14

#14

BROWN

WHITE

LABELED

MOTOR START

BLACK

WHITE

FAN CIRCUIT

 

SQ "D"

 

 

 

 

 

 

 

 

125-01-0271

 

 

R

C

CONDENSING UNIT RLA= 9.6A

MCC= 15.0A

TECUMSEH HGA9443YXAXB 115VAC, 60HZ 225-03-0104

BUNDLE

BLACK WHITE

 

ORANGE

 

 

LABELED

 

 

LIGHT CIRCUIT L1 N

NOTE:

 

~120 VAC - 60 Hz.

PRE-LIMINARY,

 

MCA= 1.3A

SUBJECT TO

 

MOP= 15A

CHANGE

 

 

L1 N

L1 N

~120 VAC - 60 Hz.

~120 VAC - 60 Hz.

MCA= 1.3A

MCA= 12A

MOP= 15A

MOP= 15A

BUNDLE BLUE LABELED

CONDENSING UNIT CIRCUIT

?

REVISIONS:

 

 

DRAWN BY:

JESSE RIOS

PROJECT TITLE: Q1-DC-XS/Q1-DS-XS

DRAWING #: W1750034-07

Hussmann Corporation, Int'l.

#:

DESCRIPTION:

DATE:

BY:

CHECKED BY:

 

DATE: 03/8/07

 

 

 

 

A

Updated dwg; removed ballast fuse

5/10/07

JR

PRODUCTION ORDER #:

DRAWING TITLE:

 

 

13770 Ramona Avenue

 

 

Chino, CA. 91710

 

 

 

 

FILE LOCATION:

Q1-DC-9S/Q1-DS-9S

 

 

(909)-590-4910 Lic.#: 644406

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 7 OF 11

Q1-DC-0508

Image 28
Contents Deli Service Case RevTable of Contents General InstructionsInstallation Cut and Plan ViewsInstallation Contd Do not USE PermagumPlumbing RefrigerationRefrigeration Contd ElectricalElectrical Contd Finishing TouchesWhen cleaning Case CleaningCleaning Glass and Mirrors User Information ContdCleaning Non-Glare GlassPlexiglass and Acrylic Care Antistatic CoatingsMaintenance Glass Replacement and Adjustment InstructionsEvaporator Fans CoilsElectrical Wiring Diagrams Q1-DCDiagrams WiringLoading Q1 DeliWiring Diagrams Contd W1750002DELIQ1 Q1DC-6RW1750003 Q1DELILoading 115 L1 4.9 #.# L2 #.# #.# L3 #.# #.#L1 6.7 #.# L2 #.# #.# L3 #.# #.# W1750005Loading Contd W1750006W1750026 Be GroundedW1750007 Diagrams ContdQ1-DC-6R Wiring Diagrams Be Grounded115 L2 L3 W1750009115 V L1 6.1 L2 L3 DWG # W1750010 Wiring Q1-DC-XS/Q1-DS-XSQ1-DC-4S/Q1-DS-4S Project Title Q1-DC-XS/Q1-DS-XS Q1-DC-5S/Q1-DS-5SPRE-LIMINARY Subject toQ1-DC-6S/Q1-DS-6S 20392457 4W .29AQ1-DC-7S/Q1-DS-7S Subject to ChangeQ1-DC-8S/Q1-DS-8S Q1-DC-9S/Q1-DS-9S Q1-DC-10S/Q1-DS-10S M MQ1-DC-11S/Q1-DS-11S Tecumseh HGA9462ZXDXM 115VAC, 60HZL2 L3 Gfci W1750034-010Appendix A. Temperature Guidelines Refrigerated AppendicesAppendix B. Application Recommendations Refrigerated Open DisplayAppendices Contd Appendix D. Recommendations to User RefrigeratedAppendices Contd Service Record