Q1-DC-0508

Installation (Cont'd)

5.Apply liberal bead of case joint sealant (butyl) to first case. Sealant area is shown using a dotted line in illustration in Step 8. Apply heavy amount to cover entire shaded area.

DO NOT USE PERMAGUM!

It is the contractor’s responsibility to install case(s) according to local construction and health codes.

6.Slide second case up to first case snugly. Then level second case to the first case so glass front, bumper and top are flush.

7.To compress butyl at joint, use two Jurgenson wood clamps. Make sure case is level from front to back and side to side on inside bulkheads at joint.

8.Attach sections together via the bolts pictured in the illustration below.

9.Apply bead of butyl to top of bulkheads

and slip on stainless steel bulkhead cap. Also apply silicone to seam between overhead light tubes.

10.Use finger to smooth silicone as thin as possible at masking tape on inside and outside of rear mullion (apply additional silicone if necessary). Remove tape applied on line #4.

11.Remove front, back and end shipping braces.

Q1-DC Refrigerated Wedges and Standard Cases Line-up taper pins and line-up plates with holes on adjoining case. Bolting is located at the rear of the case, behind the air discharge wall, and behind the front body panel. The cases are bolted together in front by means of a bracket located behind the front panel. Remove the front panel by unscrewing these bottom screws.

Do not use bolts to pull cases together.

LINE-UP PLATE

(INSERT INTO VERTICAL SLOT)

LINE-UP TAB

(AT BACK OF BUMPER)

FRONT CASE BOLT (UPPER 3/8" HOLE)

FRONT BODY PANEL REMOVED

FOR ACCESS TO FRONT CASE BOLTING

LINE-UP PLATE

(INSERT INTO ALUMINUM PROFILE)

CASE BOLTING

USE 1/4"- 20 X 1 1/2" SCREW AT TOP

LINE-UP PIN

(INSERT INTO OUTER 1/2" HOLE)

CASE BOLTING (UPPER EXTERIOR FRAME)

USE 3/8" X 5 1/2" BOLTS OR 3/8" ALLTHREAD

CASE BOLTING (MULTIPLE 3/8" HOLES)

ACCESS BEHIND AIR DISCHARGE WALL

Q SERIES CASE JOINING GUIDE

Image 4
Contents Deli Service Case RevTable of Contents General InstructionsInstallation Cut and Plan ViewsInstallation Contd Do not USE PermagumPlumbing RefrigerationRefrigeration Contd ElectricalElectrical Contd Finishing TouchesWhen cleaning Case CleaningCleaning Glass and Mirrors User Information ContdCleaning Non-Glare GlassPlexiglass and Acrylic Care Antistatic CoatingsMaintenance Glass Replacement and Adjustment InstructionsEvaporator Fans CoilsElectrical Wiring Diagrams Q1-DCDiagrams WiringLoading Q1 DeliWiring Diagrams Contd W1750002DELIQ1 Q1DC-6RW1750003 Q1DELILoading 115 L1 4.9 #.# L2 #.# #.# L3 #.# #.#L1 6.7 #.# L2 #.# #.# L3 #.# #.# W1750005Loading Contd W1750006W1750026 Be GroundedW1750007 Diagrams ContdQ1-DC-6R Wiring Diagrams Be Grounded115 L2 L3 W1750009115 V L1 6.1 L2 L3 DWG # W1750010 Wiring Q1-DC-XS/Q1-DS-XSQ1-DC-4S/Q1-DS-4S Project Title Q1-DC-XS/Q1-DS-XS Q1-DC-5S/Q1-DS-5SPRE-LIMINARY Subject toQ1-DC-6S/Q1-DS-6S 20392457 4W .29AQ1-DC-7S/Q1-DS-7S Subject to ChangeQ1-DC-8S/Q1-DS-8S Q1-DC-9S/Q1-DS-9S Q1-DC-10S/Q1-DS-10S M MQ1-DC-11S/Q1-DS-11S Tecumseh HGA9462ZXDXM 115VAC, 60HZL2 L3 Gfci W1750034-010Appendix A. Temperature Guidelines Refrigerated AppendicesAppendix B. Application Recommendations Refrigerated Open DisplayAppendices Contd Appendix D. Recommendations to User RefrigeratedAppendices Contd Service Record