SAFETY PRECAUTIONS

Installation Precautions

Warning

Do not install, remove and reinstall the unit by yourself.

Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.

Caution

This air conditioner must be earthed. Improper grounding will cause electric shock.

Ensure that the drainage piping is connected properly. Otherwise, water will leak.

Current leakage protection equipment must be installed. Otherwise, electric shock or fire may occur.

Do not install the unit in a potentially explosive atmosphere.

Caution

This sign warns of injury or damage to property.

The instructions to be followed are classified by the following symbols:

This symbol denotes

an action that is

PROHIBITED.

Operation Precautions

Do not share power outlet.

Do not modify power cord.

Do not use an extension cord.

Do not operate with wet hands.

Do not operate or stop the unit by inserting or pulling out the power plug.

Do not insert finger or other objects into the indoor or outdoor unit.

Do not attempt to repair the unit by yourself.

Do not use rechargeable (Ni-Cd) batteries.

Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.

Warning

Insert the power plug properly.

Use specified supply cord.

If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Remove the batteries if the unit is not going to be use for a long period of time.

New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.

In case of emergency or abnormal condition (burnt, smell, etc) occurs, turn off the power supply and unplug.

These symbols denote

actions that are

COMPULSORY.

Do not pull the cord to disconnect the plug.

Do not wash the unit with water, benzene, thinner or scouring powder.

Do not use for other purposes such as preservation of food.

Do not use any combustible equipment at airflow direction.

Do not sit or place anything on the indoor or outdoor unit.

Do not expose directly to cold air for a long period.

Caution

Ventilate the room regularly.

Pay attention as to whether the installation rack is damaged after long period of usage.

Switch off the power supply and unplug before cleaning or servicing.

Turn off the power supply and unplug if the unit is not used for a long period of time.

Safety Regulation

Operation Condition (OC)

 

 

 

The appliance is not intended for use by young children or infirm

 

Use this air conditioner under the following temperature

person without supervision. Young children should be supervised to

 

range.

 

 

 

 

ensure that they do not play with the appliance.

 

 

 

 

 

 

 

DBT: Dry Bulb Temperature

Indoor

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

Replacement or installation of power plugs shall be performed by

 

 

 

 

 

 

WBT: Wet Bulb Temperature

DBT

WBT

DBT

WBT

authorized/qualified personnel only. The wires in this mains lead are

 

 

 

 

 

 

 

coloured in accordance with the following code:

 

Maximum Temperature (COOL)

32

23

43

26

 

 

 

 

 

 

 

 

 

(GB Standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Temperature (HEAT)

30

24

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Temperature (COOL)

16

11

16

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Temperature (HEAT)

16

-5

-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Different countries may have different colour coding for the wires.

39

Image 1
Contents Installation Precautions Safety PrecautionsOperation Precautions Safety Regulation Operation Condition OCProduct Overview Remote ControlIndoor Unit Outdoor UnitAuto,Heat,Cool,Dry HOW to OperateSelect the desired operation Start the operationPow erful, Quiet, Ion, Fan Speed Air Sw ing PowerfulION FAN SpeedCancel TimerTimer Front Panel Care & CleaningAIR Filter Supersonic AIR Indoor Unit Purifying Device

CU-W12DKR, CU-W9DKR, CU-W7DKR, CS-W9DKR, CS-W7DKR specifications

Panasonic has established itself as a prominent player in the HVAC industry, continually delivering innovative cooling and heating solutions. Among their latest offerings are the CS-W12DKR, CS-W7DKR, CU-W9DKR, CU-W7DKR, and CU-W12DKR units, designed to enhance comfort and energy efficiency in residential and commercial spaces.

The CS-W12DKR and CS-W7DKR are wall-mounted indoor units that boast sleek designs, making them a stylish addition to any interior. Designed for versatile installation, these units efficiently blend into various decor styles. Both models utilize advanced airflow technology to ensure optimum distribution of conditioned air, minimizing hot and cold spots within the room.

One of their standout features is the inverter technology, which enables these units to operate at varying speeds, providing precise temperature control while significantly reducing energy consumption. This technology allows the air conditioning system to adjust to the cooling or heating needs of the space, resulting in lower electricity bills and an environmentally friendly operation.

The CU-W9DKR, CU-W7DKR, and CU-W12DKR are the corresponding outdoor units, engineered to work seamlessly with their indoor counterparts. Equipped with durable compressors, these exterior units are built to endure harsh weather conditions, ensuring reliability throughout the year. The high-performance rotary compressors in these models deliver powerful cooling and efficient heating capabilities, while also contributing to a quieter operation.

Energy efficiency is a hallmark of Panasonic’s design philosophy. These models have earned high Energy Efficiency Ratio (EER) ratings, reflecting their ability to convert energy into cooling or heating power effectively. The inclusion of R32 refrigerant is a significant aspect of these units, as R32 is not only more efficient than traditional refrigerants but also has a lower global warming potential.

In addition to performance and efficiency, ease of maintenance was a priority in the design of these units. The user-friendly controls and easy-access panels for cleaning filters and performing repairs simplify routine maintenance tasks, ensuring optimal performance over time.

In conclusion, the Panasonic CS-W12DKR, CS-W7DKR, CU-W9DKR, CU-W7DKR, and CU-W12DKR units epitomize a perfect blend of cutting-edge technology, energy efficiency, and user convenience. With these models, Panasonic continues to lead the way in providing sophisticated solutions for comfortable living and working environments.