E&J GF0600050REVE06 manual Operating instructions

Page 14

V Operating instructions

Read and understand all safety precautions before operating your wheelchair.

1.Charge the batteries fully before use. For battery installation and charging information, refer to Sec- tion VII, BATTERIES.

2.Engage the drive wheels by turning the drive engagement levers to the outside. See the labels that specify ON and OFF on the cowl next to the drive engagement levers; ON for engaged, and OFF for disengaged. The drive engagement levers are located:

Front wheel drive: Toward the front of the wheelchair. Drive engagement levers are pointing toward the rear of the wheelchair when engaged and inward when disengaged.

Rear wheel drive: Toward the rear of the wheelchair. Drive engagement levers are pointing to- ward the front of the wheelchair when engaged and inward when disengaged.

3.With the joystick in neutral, turn the hand control ON/OFF button ON.

4.Adjust to a low speed or drive profile (if drive profiles have been programmed).

5.Move the joystick gently in the direction in which you wish to travel. If you desire a higher speed, adjust the speed/profile increase button.

6.To stop the wheelchair, release the joystick to the neutral (center) position. The control system will bring the wheelchair to a smooth stop. Upon stopping, electromechanical park brakes will engage to prevent the wheelchair from rolling.

7.Attempting to overcome a stall condition may trip the circuit breaker located in the base end cover. In the event of an overload, the circuit breaker button will pop out. To reset the circuit breaker, push the button in.

Front wheel drive: The base end cover / circuit breaker is located at the rear of the wheelchair.

Rear wheel drive: The base end cover / circuit breaker is located at the front of the wheelchair.

14

GF0600050RevE06, August 2006

Everest with Captain Seat Owner's Manual

Image 14
Contents Everest Contents Introduction II Important safety precautions GF0600050RevE06, August GF0600050RevE06, August Powered Wheelchair Electromagnetic Interference EMI Electromagnetic interference EMI from radio wave sourcesEMI Warnings Important InformationTransfer activities III Handling tipsBalance Reaching / bendingAscent BackwardRamps and Inclines DescentPower drive system IV Getting startedJoystick Controller cableHorn button Battery indicatorMaximum speed / profile indicator Speed / profile decrease buttonOperating instructions VI Adjustments Adjust hand control extension Backward / forwardAdjust hand control extension-change sides Adjust arm space from seat frame width between arms Adjust back angle Back Fold back downAdjust headrest height HeadrestRemove seat refer to the pictures at right Install seat refer to the pictures at rightSeat Adjust seat height refer to the pictures on previous Install cowl refer to the picture above Cowl Remove cowl refer to the picture at rightAdjust footplate extension length see picture at right Adjust individual footplate extension lengthGuidelines to extending battery life VII BatteriesStatus indicator Battery chargerBattery charger front panel Output cable and connector Battery capacity level indicatorSafety-charging the batteries Charging the batteries Remove and install batteries Adjust battery brackets if necessary Install batteriesGF0600050RevE06, August Regular battery maintenance Clean batteries Clean battery terminalsViii Maintenance Do-it-yourself maintenanceCharge batteries List of tools and suppliesGeneral care Check joystickControl system cable connections Front wheel drive Control system cable connections Rear wheel drive Check tires Clean frameCheck & clean upholstery Check controller & park brakesCheck bearings Check caster forksInspect motor brushes IX Troubleshooting General Troubleshooting BatteriesTroubleshooting controller General diagnostic guideBattery indicator control system status display Wheelchair will be operable when the following faults occurBattery indicator control system fault display Troubleshooting battery charger Power outlet and wheelchair battery charger receptacleGF0600050RevE06, August Limited Warranty Warranty PeriodsGF0600050RevE06, August XI Index

GF0600050REVE06 specifications

E&J GF0600050REVE06 is a high-performance product known for its innovative features and advanced technologies. Designed to cater to the needs of both commercial and residential applications, this model has gained recognition for its reliability and efficiency in various environments.

One of the standout features of the E&J GF0600050REVE06 is its robust construction. Built with high-quality materials, it ensures durability and longevity in operations, making it a smart investment for users seeking long-term performance. The design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly into different settings.

The E&J GF0600050REVE06 boasts significant energy efficiency, which is becoming increasingly important in today's eco-conscious market. With its state-of-the-art energy conversion technologies, it minimizes waste and enhances overall energy usage, providing significant savings on operational costs over time. Users can expect lower utility bills without compromising on performance, a crucial consideration for budget-conscious individuals and businesses alike.

Another noteworthy characteristic of this product is its user-friendly interface. Equipped with advanced control systems, it allows for easy monitoring and adjustment, catering to the varying needs of its users. Whether it's adjusting settings for optimal performance or accessing diagnostic features, the intuitive layout ensures that even those with minimal technical knowledge can operate the device effortlessly.

Moreover, the E&J GF0600050REVE06 incorporates several safety features, ensuring peace of mind during operation. These include automatic shut-off systems and temperature regulation, which protect the unit and the surrounding environment from potential hazards. This focus on safety not only enhances user confidence but also promotes a safer working environment.

Additionally, the technology behind the E&J GF0600050REVE06 supports seamless integration with other smart devices. This capability allows users to control and monitor the device remotely, facilitating greater flexibility and convenience in management.

In conclusion, the E&J GF0600050REVE06 stands out as a leading choice for those seeking advanced technology, energy efficiency, and a commitment to safety and durability. Its thoughtful design and innovative features make it an essential tool for modern users, enhancing productivity and operational effectiveness. With its excellent performance and user-centric approach, the E&J GF0600050REVE06 really sets itself apart in a competitive market.