Tanita BD-815U instruction manual Output Data Format

Page 13

Output Data Format (continued)

Pounds/ounces (lb•oz) mode (transmission data)

Transmission data is output immediately after measurement regard-

 

 

GB less of the status at the reception side (e.g. PC).

Therefore, the recep-

GB

tion side must always be ready to receive data before any measure-

 

ments are taken.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. When the display is held

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

Header

 

Output data (ASCII code)

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control data

 

 

 

{0

 

Fixed at 16

 

 

 

 

 

 

 

 

 

 

Control data

 

 

 

~0

 

Fixed at 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model No.

 

 

 

MO

 

"XXXXXX"

8-byte fixed length (“BD-815”)

 

 

 

 

Body weight

 

 

 

Wo

 

XX.XX.X

5~7 bytes variable length (unit: lb•oz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20

21 22 23 24 25 26 27

 

 

 

{ 0 , 1 6 , ˜ 0 , 1 , M O , " B D - 8 1 5 " , W o , 9

 

28 29 30 31

32

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

3

.

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. When the Weight Gain key is pressed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

Header

 

Output data (ASCII code)

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight gain

 

 

 

Go

 

XXX.XX.X

5~8 bytes variable length (unit: lb•oz)

 

 

 

Memorized weight

 

Ro

 

XX.XX.X

5~7 bytes variable length (unit: lb•oz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18

19

20

 

 

 

 

G o , 0 . 3 . 5 , R o , 8 . 1 5 . 7

CR

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C. When the Recall key is pressed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

Header

 

Output data (ASCII code)

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

 

 

 

 

Memorized weight

 

Ro

 

XX.XX.X

5~7 bytes variable length (unit: lb•oz)

 

 

1

2

3

4

5

6

7

8

9

10

 

11

 

 

 

 

 

 

 

 

 

 

R o , 8 . 1 5 . 7

CR

 

LF

 

 

 

 

 

 

 

 

 

Note

•Commas (,) are used to separate data.

•Terminator (end of data) is CR (ASCII code: 0DH), LF (ASCII code: 0AH).

24

25

Image 13
Contents BD-815U Professional Baby ScaleContents Safety Notes MaintenanceInstructions for Measurement Safety NotesAttachment Baby Basket Attachment & RemovalRemoval Front Confirmation of accessoriesDisplay Panel BackLevel gauge Check Using batteriesMeasurement instructions When tare is not specifiedExtended Display Function Tare weighing function Canceling the tare functionMemory cancellation Display Weight GainMemory Function Memory Value Recall MethodAuto Power Off Time Various Setting MethodsDisplay Hold Time When the Weight Gain key is pressed When the display is heldWhen the Recall key is pressed Output Data FormatOutput Data Format Check points GB ProblemTanita Corporation. All Rights Reserved BD8157001