Panasonic WJ-MPU955A manual Running Sequence, Tour Sequence, Group Sequence

Page 62

Running Sequence

Tour Sequence

The following functions are available if a Tour Sequence has been previously configured through the admin console. Any Tour Sequence can be assigned to any monitors.

1.Select the desired monitor. (Refer to p. 56 Monitor Selection.)

2.To select the desired Tour Sequence number, press the numeric buttons.

MON

1

CAM

0123

Unit:01

00512

Note: When you have selected a wrong number, press the CLEAR button to clear the numeric input.

3.Press the TOUR SEQ/GROUP SEQ button. The Tour Sequence will run in forward direction on the active monitor, and the Tour Sequence number with "R" (Running) sign is displayed on the active monitor.

MON A001T0001R CAM

0123 Unit:01 00512

Note: The messages on the LCD indicate the following.

Annn: Area No.

Tnnnn: Tour Sequence No.

R: Running

4.To pause the sequence, press the SEQ PAUSE/SEQ STOP button.

The "P" (Pausing) sign will be displayed beside the Tour Sequence number area on the active monitor, and "P" will appear beside the Tour Sequence number.

MON A001T0001P CAM

0123 Unit:01 00512

Notes:

To switch to the next sequence step, press the + button during sequence pause.

To switch to the previous sequence step, press the

– button during sequence pause.

To resume the sequence, press the TOUR SEQ/GROUP SEQ again.

5.To return to spot monitoring, press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button.

Note: You can also return to spot monitoring by select- ing a camera.

Group Sequence

The following function is available only if a Group Sequence has been previously established through the admin console. A Group Sequence determines the assignment of monitors and cameras.

1.Press the numeric buttons to select a desired Group Sequence number.

MON

1

CAM

0123

Unit:01

00512

Note: When you have selected a wrong number, press the CLEAR button to clear the numeric input.

2.Press the TOUR SEQ/GROUP SEQ button while holding down the SHIFT button. The Group Sequence will run in forward direction on the assigned monitors, and the Group Sequence number with "R" (Running) sign is dis- played on each monitor.

MON A001G0001R CAM

0123 Unit:01 00512

Notes:

The messages on the LCD indicate the following. Annn: Area No.

Gnnnn: Group Sequence No.

R:Running

When you select another monitor and starts a group sequence, the Group Sequence number will not be displayed on the LCD.

3.To pause the sequence, select one of the monitors that are being run on the selected group sequence. Then press the SEQ PAUSE/SEQ STOP button.

The "P" (Pausing) sign will be displayed beside the Group Sequence number area on the active monitor.

MON A001G0001P CAM

0123 Unit:01 00512

Notes:

To switch to the next sequence step, press the + button during sequence pause.

To switch to the previous sequence step, press the

– button during sequence pause.

4.To return to spot monitoring, select one of the monitors that are being run on the selected group sequence. Then, press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button.

62

Image 62
Contents Operating Instructions For Your Safety Please Read the Following Text CARE- Fully For Canada Important Safety Instructions Trademarks and Registered Trademarks Disclaimer of WarrantyLimitation of Liability Network SecurityContents Appendix GX System Ntsc model only FeaturesPreface SystemPrecautions Document Convention WJ-MPU955A ReferencesNotification about System Units This page intentionally left blank Page Operator Functions Main FeaturesVideo Switch and Video Routing Video Camera FunctionsEvent Operations Alarm Programming and HandlingTour Sequences Digital Input and Output FunctionsGX System Examples Ntsc Model Only Standard SystemRedundant System 192.168.1.10Available System Controllers Ethernet ControllersSX650 SubNode This page intentionally left blank Detailed Product Description Front View Major Operating Controls and Their FunctionsLayout Rear ViewPanel Details This page intentionally left blank Installations Installations Mounting into the RackConnection of GX System Ntsc Model only Connection with System Devices Ethernet-Based Controller SetupFor Manual Switchover Operation System ControllersWhen Adding a Redundant CPU to a Standard System Active Indicator MeaningsFor Automatic Switchover Operation Updating System SoftwareConnect with CPU Setup from Admin ConsoleDigital Video Encoder Devices Setup Encoder Itself DNSSetup Decoder Itself Digital Video Decoder DevicesTime Management Utility Setup Layer 3 Switching L3SWAdmin Console Digital Disk Recorders Setup Digital Disk Recorder ItselfComm Settings for communication with the CPU DhcpFull Matrix System Matrix Switcher WJ-SX650 Series Network Board InstallationVertical Interval Synchronization Mode Switch SettingsAdmin Console Setup Video Connection between SubNode 2 and SubNode 3 Bridge Connect with Each SX650 SubNode via Coaxial CablesVideo Connection between SubNode 1 and SubNode 3 Bridge Video Connection between SubNode 4 and SubNode 6 BridgeLoop-thru Connection between SubNode 1 and SubNode Loop-thru Connection between SubNode 2 and SubNode Configuration Details System Database Available ConfigurationsConfiguration File Modification Default SYS.INI Contents Procs section OSD sectionLOG section RS232ALARM sectionUnit section TimeDateFormat=1Routing section Alarmtextdisplay sectionSystem section Errorp section Sntp sectionLogical # Control Video Compensation Model Switch PortsArea Priority Boot File Model PortArea Local Switch Port Password Priority Timeout Name ClassDatabase Contents GX System Ntsc Model Only 172.18.0.200 Unit Digital Channels Cam Address Bitrate Switch Port Logical Model VideoOperating Procedures with WV-CU950 Blinking Default Status LCD Display After LoginLCD Display Descriptions Messages Displayed onOperation End Logout Login and LogoutOperation Start Login ID Display FunctionCamera Selection Monitor Selection and Camera SelectionMonitor Selection Monitor LockDisplay Setting for Controller Adjustment of LCD Display and BuzzerPan/Tilt Control Camera Site Accessories ControlLens Control Call Preset Position Wiper ControlAuxiliary Control Operating ProcedureDefroster Control Other Camera Functions Camera Function ControlCamera Function Shortcut Function MON CamF075 CAM Unit01Group Sequence Running SequenceTour Sequence Monitor Display Control Alarm Selection Alarm ControlExample of Alarm Input Resulting Alarm Activation Alarm Arming ControlTo Operate Alarm-related Camera ACK To Cancel AlarmsMON AlarmHist CAM 012300512 Displaying WJ-HD300A Series WJ-HD300A Series ControlRecorder Selection Controlling Digital Disk Recorder WJ-HD300A SeriesRepeat Playback Multiscreen Segment SwitchingElectronic Zooming EL-ZOOM Playing the Latest Recorded ImageSearch Playback Search Mode Thumb Text CopySearch Mode List Text Copy Nr-A Cp-A Cpy1 Cpy2 Manual RecordingAvailable buttons and functions Data Copy window Main unit Date-and-time Search PlaybackRecording event search JogDial counterclockwise Decrements a parameterMain unit 3D joystick rightward B Moves the cursor to the right VMD searchAvailable controls and functions Main unit Marking search TIME&DATE CAMThumbnail window Canceling FiltersTime & Date Search Playback Mmm/DD/YYYY Hhmm Mar/17/2004 1200 AMSystem Function HD300 Setup 5OffHD300 Setup 5On Off Other FunctionsDisk Selection Canceling FiltersHD300 A-B Repeat Start End Cancel HD300 DiskSelect Nr-A Cp-A Cpy1 Cpy2To Recall Menu Functions Menu Function DescriptionsMenu Functions CamMenu On 5Off Rst A.RstBW Mode Camera SetupAuto Mode Menu Function DetailsOSD Control Group PresetPatrol Learn Digital OutputF3 Blk AlmStat On Off BlkVL Stat 009 On Off Blk Example SysStat On Off BlkVL Hist 011 On Off Blk Controller ID Area ChangeOperator ID System VersionAppendix CPU-Related Problems TroubleshootingPower Related Failure When using Standard System No Redundant CPUMPEG2 System Controller-Related ProblemsEncoder and Decoder-Related problems Ntsc model only CD-ROM SpecificationsStandard Accessories For business users in the European UnionOsaka, Japan Http//panasonic.net

WJ-MPU955A specifications

The Panasonic WJ-MPU955A is a sophisticated multipurpose processor designed for professional video and graphics applications. It serves as a powerful solution for broadcasters and production teams seeking to elevate their content through high-quality imaging and advanced processing capabilities. This device stands out in the competitive landscape of video processing technology, combining robust features with cutting-edge innovations.

One of the defining features of the WJ-MPU955A is its versatile input and output configurations. It supports a wide range of video formats, enabling users to seamlessly switch between HD, SD, and even 4K resolutions. This flexibility is crucial for addressing the diverse demands of modern broadcasting environments, where various content sources and formats are frequently encountered.

The WJ-MPU955A employs high-performance processing algorithms that enhance image quality by reducing noise, improving color accuracy, and providing smooth transitions and effects. The advanced video scaling technology ensures that images are rendered with exceptional clarity and detail, regardless of the source resolution. This is particularly beneficial in live production scenarios, where real-time processing is essential.

Another significant characteristic of the WJ-MPU955A is its user-friendly interface, which simplifies operation and allows for efficient management of complex setups. The integrated control panel is designed to facilitate quick adjustments and modifications during a live broadcast, ensuring that production teams can maintain a high level of performance under pressure. Furthermore, the device can be integrated into larger production environments, allowing for centralized control via external systems.

In addition to its processing capabilities, the WJ-MPU955A supports comprehensive monitoring features. Users can visualize and analyze video signals in real-time, ensuring that any issues are promptly identified and addressed. This proactive approach to quality control is vital for maintaining broadcast standards.

The WJ-MPU955A also incorporates advances in connectivity technology, making it compatible with various network protocols and streaming standards. This ensures that content can be delivered across multiple platforms seamlessly, enhancing the overall viewing experience for audiences.

In summary, the Panasonic WJ-MPU955A is an exceptional multipurpose processor, offering a combination of advanced video processing, user-friendly controls, and versatile connectivity. Its robust features make it an ideal choice for professionals in the broadcasting and production industries, providing the tools needed to create high-quality content efficiently and effectively.