If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device.

Problem/Possible Cause

Solution

No display

 

Power is not connected.

Ensure the power cable is connected and the power switch (if

 

available) is on.

Insufficient air delivered from the VPAP device

Ramp or Settling time is in use.

Wait for air pressure to build up or change ramp time.

Air filter is dirty.

Replace air filter.

Air tubing is not connected

Check air tubing.

properly.

 

Mask and headgear are not

Adjust position of mask and headgear.

positioned correctly.

 

Device does not start when you breathe into the mask

Breath is not deep enough to

Take a deep breath in and out through the mask.

trigger SmartStart/Stop.

 

There is excessive leak.

Adjust position of mask and headgear.

 

Air tubing not connected properly. Connect firmly at both ends.

SmartStart/Stop is disabled.

Enable SmartStart/Stop.

Note: SmartStart/Stop is not

 

available if you are using a Full

 

Face Mask or if Leak Alert is

 

enabled.

 

Device does not stop when you remove your mask

SmartStart/Stop is not enabled.

Enable SmartStart/Stop.

Note: SmartStart/Stop is not

 

available if you are using a Full Face Mask or if Leak Alert is enabled.

SmartStart/Stop is enabled but the flow generator does not stop automatically when you

remove your mask

Incompatible mask system being

Only use equipment recommended by ResMed.

used.

 

Pressure rises inappropriately

 

Talking, coughing or breathing in

Avoid talking with a nasal mask on, and breathe as normally as

an unusual manner.

possible.

Mask cushion is buzzing against

Adjust the headgear.

the skin.

 

Cushion seated incorrectly

Adjust headgear or re-fit cushion.

causing excessive leak.

 

Humidifier control dial set too

Turn humidifier control down and empty the water from the air

high, resulting in accumulation of

tubing.

water in the air tubing.

 

English

Troubleshooting 13

Image 16
Contents User Guide EnglishVpap ST Contents Introduction Vpap SystemContraindications Adverse EffectsHumidifier MasksResScan Data Card Setting up your Vpap Using the Vpap Auto 25, Vpap ST & Vpap SSupplemental Oxygen How to Use the Control Panel Attaching a H4i HumidifierDown RightUsing the Menus VAuto mode CPAP, S, ST & T modesHow to Select the Mask Type SmartStartStopping Treatment Starting TreatmentExample Reminders on the Vpap LCD Mask-fit star ratingUsing the Data Card Copying Data onto a Data CardTraveling with the Vpap Auto 25, Vpap ST & Vpap S Cleaning and Maintenance DailyWeekly MonthlyServicing Troubleshooting Problem/Possible Cause SolutionData Card Card Error Remove Card Symbols Which Appear On The Device Technical SpecificationsTechnical Specifications General Warnings and Cautions General Warnings and Cautions Separation distance according to frequency of transmitter mPage Limited Warranty

AUTO 25, ST, S specifications

The ResMed S, ST, and AUTO 25 devices represent a significant advancement in sleep therapy technology, designed to enhance the treatment of patients with obstructive sleep apnea (OSA) and other sleep-related disorders. These devices are part of ResMed's commitment to improving patient outcomes through innovative breathing solutions.

One of the standout features of the ResMed S, ST, and AUTO 25 is their adaptive pressure support capabilities. The devices utilize advanced algorithms to automatically adjust air pressure based on the user’s breathing patterns. This real-time responsiveness ensures that patients receive optimal therapy tailored to their specific needs, allowing for a more comfortable and effective treatment experience.

The automatic titration feature of the AUTO 25 is particularly noteworthy. It continuously monitors the patient’s airflow and adjusts pressure levels throughout the night. This dynamic capability not only enhances compliance but also helps to prevent apnea events more effectively than fixed-pressure devices.

In terms of comfort, the ResMed S, ST, and AUTO 25 feature a ramp function that gradually increases pressure from a lower starting point. This allows patients to fall asleep more comfortably before reaching the prescribed therapeutic pressure. The quiet operation of these devices adds to patient comfort, ensuring a peaceful night’s sleep for both the user and their partner.

Connectivity is another key characteristic of the ResMed S, ST, and AUTO 25 devices. Equipped with wireless technology, these devices allow for seamless data transfer to healthcare providers. This connectivity facilitates remote monitoring, enabling clinicians to track therapy progress and make necessary adjustments without the need for in-person visits.

Additionally, the user-friendly interface simplifies setup and navigation. Intuitive controls and a clear display make it easy for users to monitor their therapy progress and understand their treatment journey. The devices are designed with patient education in mind, providing users with essential information about their sleep patterns and therapy effectiveness.

ResMed also places a strong emphasis on the durability and reliability of its devices. The S, ST, and AUTO 25 are constructed with high-quality materials and are rigorously tested to ensure long-lasting performance. Maintenance is straightforward, with easily accessible components to facilitate cleaning and upkeep.

In summary, the ResMed S, ST, and AUTO 25 devices represent a comprehensive solution for sleep therapy, combining innovative technologies, user-friendly features, and reliable performance to improve patient care. Their intelligent adaptability, advanced monitoring, and enhanced comfort make them a preferred choice for individuals seeking effective treatment for sleep disorders. With ResMed’s ongoing commitment to research and development, patients can expect even greater advancements in sleep therapy solutions in the future.