WARNING

Do not touch a temperature probe sheath when measuring excessively high or low temperatures, or toxic substances.

WARNING

Do not attempt to measure temperatures beyond the range of the probe being used. Probe damage or personal injury could result from exceeding a probe's maximum temperature rating.

WARNING

The American National Safety Institute (ANSI) states that a shock hazard exists when probes or sensors are exposed to voltage levels greater than 42VDC or 42V peak AC. Do not use this instrument where voltages at the measurement sur- face exceed these levels.

WARNING

Do not substitute a metal part for the nylon screw in the rear case. Doing so will degrade electrical isolation of the case.

WARNING

The battery is accessible through a cover on the back of the instrument. To avoid electrical shock hazard, disconnect all temperature probes and sensors and turn the unit off before removing the cover.

WARNING

Never use this instrument or any probe or sensor inside a microwave oven.

CAUTION

Avoid making sharp bends in probe or sensor lead wires. Bending lead wires at a sharp angle can damage the wire causing probe failure.

8

Image 10
Contents User’sGuide Omega.comTM Table of Contents Common Specifications General InformationTemperature Coefficient Page Model CL24 Unique SpecificationsModel CL23A/CL23EC Model CL25/CL25ECManual Addenda FeaturesModel CL27/CL27EC Safety Precautions Safety InformationUnpacking Your Unit Page Battery INSTALLATION/REPLACEMENT Battery InstallationMemory Backup Operation with Rechargeable BatteryOperating Instructions Diagnostics and Error MessagesProblem Likely Cause Initial Turn onKeypad Meter Mode Operation Thermocouples Set-Up OPRMeter Mode Operation RTD, Thermistor & Ohms Set-Up HoldData Logging and Recall To Save Readings To Recall ReadingsTo Erase Data Locations Meter Mode Calibrator Mode Operation Thermocouples Set-UpCalibrator Mode Operation RTD, Thermistor & Ohms Set-Up CHANGE/ENTER, 2, 1, 2, 0, CHANGE/ENTERWire Resistance Simulation Storage and Recall of Calibrator Settings To Store OutputsTo Erase Set-Up Locations Calibrator Mode To Recall OutputsStep Function Ramp Function CL25 and CL27Thermocouple Calibration Test Equipment Required Service InformationCalibration Procedures Ambient ConditionsPage Calibration Adjustments Calibrator-Mode Zero & Gain Adjustments Sensor Meter-Mode Zero & Gain Adjustments Sensor StepInput Adjust Reading Output Adjust ReadingCalibration Setup, Copper Mode Resistance Calibration Test Equipment RequiredResistance Calibration Setup RTD-100 390.26Ω Calibration of Meter-Mode Resistance Functions Output Input Adjust Verify ReadingInput Adjust Verify Reading RTD-Thermistor Sensor Unit StepCalibration Verification Model Software Revision Equipment RequiredPage Page Alloy Mode Verification Procedure for Thermocouple Functions Page Mechanical Parts Diagram Calibration Procedures Page Page Page USAWARRANTY/DISCLAIMER Temperature

CL25, CL24, CL27, CL23A, CL26 specifications

The Omega CL series is renowned for its blend of advanced technology, design, and performance. This article delves into five prominent models: CL26, CL23A, CL27, CL24, and CL25, highlighting their main features, technologies, and characteristics.

Starting with the Omega CL26, this model is celebrated for its high sensitivity and precision. It integrates cutting-edge sensor technology that delivers accurate readings even in challenging environments. The CL26 is equipped with a user-friendly interface, enabling easy navigation through its various functions, making it suitable for both professionals and enthusiasts.

Next, the Omega CL23A is designed for versatility. This model features a compact design, allowing for easy portability without compromising on functionality. The CL23A supports multiple measurement modes, including temperature, humidity, and pressure, making it an excellent choice for those who require a multi-purpose instrument. Its robust build ensures durability, ideal for outdoor use.

The Omega CL27 stands out with its advanced connectivity features. This model is equipped with Bluetooth and Wi-Fi capabilities, allowing seamless data transfer to smartphones and tablets for real-time monitoring and analysis. The CL27’s extensive data logging capabilities enable users to track trends over time, which is invaluable for research and industrial applications.

Meanwhile, the Omega CL24 focuses on energy efficiency. With its low power consumption technology, this model extends battery life without sacrificing performance. The CL24 features an innovative display that is easy to read, even under bright sunlight. Its rugged construction makes it resistant to harsh conditions, appealing to field professionals in demanding environments.

Finally, the Omega CL25 is characterized by its high-performance analytics. This model utilizes sophisticated algorithms to provide detailed insights into the data collected, enabling more informed decision-making. It is designed with a sleek interface that not only looks modern but enhances usability for complex readings.

In summary, the Omega CL series offers a diverse range of instruments tailored to meet varying needs in both professional and personal environments. Each model boasts unique characteristics, from advanced connectivity to enhanced energy efficiency, making them reliable tools for precise measurement across industries. Whether users require portability, versatility, or detailed analytics, the Omega CL series has a solution for every requirement.