Allegro Industries 9850, 9832, 9821, 9806, 9833 AIR Driven Pump P/N, A. Grade-D Air Requirements

Page 4

S A F E T Y P R E C A U T I O N S

FOLLOW ALL WARNINGS AND CAUTIONS

ALL PUMPS:

DO NOT place oil-less air pump in an area that cannot GUARANTEE clean Grade D breathable air, per OSHA 29 CFR 1910.134 to the AABA inlet. See below for Grade D requirements.

DO NOT attempt to service the air pump while it is running or while it is connected to electrical or air power. DO NOT oil or lubricate the pump.

DO NOT kink power cord and never allow the cord to come in contact with oil, grease, hot surfaces, or chemicals. DO NOT use ungrounded electrical receptacles.

DO NOT use undersized electrical extension cords or wiring.

DO NOT use the pump as an air-filtering device for vapors, gases, or particulates. DO NOT start pump without respirator(s) and hose(s) connected to pump.

DO NOT use Vortex type cooled respirators with Allegro pumps.

DO check all airline hoses for weakness and wear before use. DO Ensure that all hose and plumbing connections are secure.

DO Ensure that the power source conforms to the requirements of your equipment.

DO remove aluminum canister on exhaust filter assembly and check that exhaust filter is firmly seated in place before startup.

AIR DRIVEN PUMP: (P/N 9850)

DO NOT attempt to service the air pump or air motor while it is in operation, and air source connected. DO NOT run air motor with less than 75 cfm at 80 psi.

DO NOT run air motor with dirty particulate filter.

DO run air motor with inline lubrication properly filled and adjusted.

DO make sure that the air pressure and volume conforms to the requirements of your equipment.

EXPLOSION PROOF PUMP: (P/N 9833)

DO NOT remove plug or cord from motor. Hazardous location plug and receptacle must be used at all times. DO NOT place pump’s inlet filter (or extension) in a hazardous location.

DO ensure proper electrical power to motor.

DO ensure proper cooling for electrical motor, to avoid heat sources in a hazardous location.

NOTE: For further information on how to operate Allegro AABA pumps with various NIOSH approved respirators, please contact our Technical Support Department.

WARNING!

DO NOT run pump without attaching the breathing hose and respirator. Failure to do so may result in a "back pressure" causing damage and/or stalling the pump.

C.G.A. Grade-D Air Requirements

Oxygen

19.5 - 23.0 %

Hydrocarbons (condensed) in mg/m3 of gas

5 mg/m3 Max.

Carbon Monoxide

10 ppm Max.

Carbon Dioxide

1,000 ppm Max.

No toxic contaminants at levels which would make the air unsafe to breathe.

2

Image 4
Contents Allegro Table of Contents NumberINTRODUCTION/DESCRIPTION Tolerances and WarningsIntroduction DescriptionAIR Driven Pump P/N A. Grade-D Air RequirementsPressure Relief Valve RPV E R ’ S I N S T R U C T I O N SInlet Extension KIT P/N AIR Pump L E R a N C E S a N D W a R N I N G SExplosion Proof Pump Specification S S P E C T I O N ALL PumpsElectrical Motors AIR Driven MotorsFlushing Instructions I N T E N a N C E FiltersAIR Driven Motor P/N R T S & a C C E S S O R I E S All Models Model A-300Models A-750, A-750TE Models A-1500TE, A-1500EX, A-4000ADTroubleshooting Electric Models If motor failsIf output air hot or pump is running hot If there is a rise in outlet pressureIf there is a drop in outlet pressure AIR Driven PumpIf low torque or speed, or motor runs hot If motor won’t turn at allLimitation of Liability WarrantyReturn Policy Ambairpumman.doc Rev C /03

9832, 9806, 9850, 9833, 9846 specifications

Allegro Industries is a renowned manufacturer, specializing in a range of high-performance portable ventilation systems that cater to various industrial needs and environments. Among their celebrated offerings are the models 9821, 9846, 9833, 9850, and 9806, each designed with unique features that enhance productivity and safety in the workplace.

The model 9821 stands out due to its lightweight portable design, making it ideal for use in confined spaces or remote locations. This model boasts a powerful motor that generates a high volume of air movement, ensuring a steady flow of fresh air even in the most challenging environments. Additionally, it incorporates a rechargeable battery option, providing convenience and flexibility for users without direct access to power sources.

In contrast, the Allegro 9846 model is engineered for heavy-duty applications. It is equipped with a robust construction that can withstand the rigors of industrial workloads. Its high-efficiency fan system is designed to deliver maximum airflow while consuming minimal energy. This model is particularly effective in large spaces where effective ventilation is essential for maintaining air quality and worker safety.

The 9833 model takes a different approach by integrating advanced filtration technologies. This model includes a multi-stage filtration system that effectively captures dust, pollutants, and other airborne particles, making it suitable for environments that require clean air standards. The compact design allows easy transport and setup, ensuring it can be deployed swiftly when needed.

Model 9850 is designed for versatility, featuring a modular design that allows users to customize airflow parameters according to their specific requirements. With dual fan capabilities and the option for daisy chaining multiple units, this model is perfect for both small and expansive operations. Its intuitive controls make it user-friendly, allowing operators to adjust settings quickly while ensuring optimal performance.

Lastly, the 9806 model emphasizes durability, featuring a rugged casing that protects internal components from damage in harsh industrial settings. It offers adjustable speed settings, allowing users to tailor airflow intensity based on the task at hand. This model is particularly well-suited for construction sites, manufacturing facilities, and emergency response applications.

Overall, Allegro Industries’ range of ventilation systems exemplifies cutting-edge engineering, providing effective air movement solutions for diverse industrial applications. Each model showcases a combination of technology, portability, and user-focused features, reinforcing Allegro's commitment to enhancing workplace safety and productivity.