Allegro Industries 9806 I N T E N a N C E Filters, Flushing Instructions, AIR Driven Motor P/N

Page 8

M A I N T E N A N C E

FILTERS:

Change inlet filter every 200 running hours or if the pressure gauge shows a drop in pressure.

Change discharge filter every 200 running hours or if the pressure gauge shows an increase in pressure.

FLUSHING INSTRUCTIONS:

1.Perform this procedure in a well ventilated area.

2.Wear solvent resistant gloves and eye protection while performing the flushing procedure.

3.Disconnect airline hose and respirator to prevent contamination.

4.Remove inlet filter assembly and pressure relief valve, to prevent damage to pump from back pressure.

5.Add 10-15 squirts of flushing solvent, Allegro P/N: 9700-11, through the inlet port opening.

6.Turn pump on and let run for 1 minute to flush out contaminants.

7.Repeat flushing procedure if pump is in extremely dirty or is under performing.

8.Replace inlet filter assembly and pressure relief valve.

9.Replace exhaust filter and inlet filter.

10.Reconnect airline hose and respirator, do not use respirator until all steps are complete.

11.Turn pump on for 10 minutes, this allows the flushing solution to dry out completely.

AIR DRIVEN MOTOR: (P/N 9850)

1.Disconnect inlet plumbing from pump and muffler assembly.

2.Add 10-15 squirts of solvent into the inlet port.

3.Rotate the shaft by hand in both directions for a few minutes.

4.Reassemble plumbing and reconnect the inlet air supply line and slowly apply pressure.

5.Flushing liquid should slowly exit the exhaust port, let run for 10 minutes

6.Reassemble exhaust assembly.

WARNING!

Keep face away from exhaust port. DO NOT flush unit with KEROSENE OR OTHER COMBUSTIBLE LIQUIDS. Personal injury and/or property damage will result.

LUBRICATION: (For Air Driven Pump Only P/N: 9850)

To lubricate the air motor (which drives air driven Model: A-400AD), use a detergent SAE #10 automotive engine oil. DO NOT lubricate air pump. For proper operation and maximum service-life, an automatic air line lubricator has been installed inline just before of the air motor.

The lubricator should be adjusted to feed one drop of oil per minute.

Lubrication is necessary for all internal moving parts and rust prevention.

Excessive moisture in the air line can cause rust formation in motor and might also cause ice to form in the muffler due to expansion of air through the motor.

The moisture problem can be corrected by installing an additional moisture separator inline.

VANE REPLACEMENT: (Consult factory prior to replacing vanes.)

To replace vanes or inspect the pump interior:

1.Remove only the endplate by removing the six bolts holding the end plate to the body.

2.Remove the endplate and the four vanes, pay attention to the direction the vanes are facing.

3.Do not remove the rotor or loosen any electric motor “through-bolts.”

4.Inspect used vanes for signs of cracking due to backpressure.

5.Inspect interior surface of chamber and rotor, for any signs of scaring or metal to metal contact.

6.Ensure surface is smooth and free of rust or contaminants, sand down surface if needed.

7.Clean with appropriate flushing solution.

8.If necessary align body to set proper clearance.

9.Insert the vanes with the beveled edge fitting the contour of the body bore of the pump.

10.The rotor should be turned while setting clearance to assure that all points on the rotor clear the body.

11.Replace the endplate and endplate bolts securely. (Do not over-tighten).

6

Image 8
Contents Allegro Table of Contents NumberINTRODUCTION/DESCRIPTION Tolerances and WarningsIntroduction DescriptionAIR Driven Pump P/N A. Grade-D Air RequirementsInlet Extension KIT P/N E R ’ S I N S T R U C T I O N SPressure Relief Valve RPV Explosion Proof Pump L E R a N C E S a N D W a R N I N G SAIR Pump Specification S S P E C T I O N ALL PumpsElectrical Motors AIR Driven MotorsAIR Driven Motor P/N I N T E N a N C E FiltersFlushing Instructions R T S & a C C E S S O R I E S All Models Model A-300Models A-750, A-750TE Models A-1500TE, A-1500EX, A-4000ADTroubleshooting Electric Models If motor failsIf output air hot or pump is running hot If there is a rise in outlet pressureIf there is a drop in outlet pressure AIR Driven PumpIf low torque or speed, or motor runs hot If motor won’t turn at allReturn Policy WarrantyLimitation of Liability Ambairpumman.doc Rev C /03

9832, 9806, 9850, 9833, 9846 specifications

Allegro Industries is a renowned manufacturer, specializing in a range of high-performance portable ventilation systems that cater to various industrial needs and environments. Among their celebrated offerings are the models 9821, 9846, 9833, 9850, and 9806, each designed with unique features that enhance productivity and safety in the workplace.

The model 9821 stands out due to its lightweight portable design, making it ideal for use in confined spaces or remote locations. This model boasts a powerful motor that generates a high volume of air movement, ensuring a steady flow of fresh air even in the most challenging environments. Additionally, it incorporates a rechargeable battery option, providing convenience and flexibility for users without direct access to power sources.

In contrast, the Allegro 9846 model is engineered for heavy-duty applications. It is equipped with a robust construction that can withstand the rigors of industrial workloads. Its high-efficiency fan system is designed to deliver maximum airflow while consuming minimal energy. This model is particularly effective in large spaces where effective ventilation is essential for maintaining air quality and worker safety.

The 9833 model takes a different approach by integrating advanced filtration technologies. This model includes a multi-stage filtration system that effectively captures dust, pollutants, and other airborne particles, making it suitable for environments that require clean air standards. The compact design allows easy transport and setup, ensuring it can be deployed swiftly when needed.

Model 9850 is designed for versatility, featuring a modular design that allows users to customize airflow parameters according to their specific requirements. With dual fan capabilities and the option for daisy chaining multiple units, this model is perfect for both small and expansive operations. Its intuitive controls make it user-friendly, allowing operators to adjust settings quickly while ensuring optimal performance.

Lastly, the 9806 model emphasizes durability, featuring a rugged casing that protects internal components from damage in harsh industrial settings. It offers adjustable speed settings, allowing users to tailor airflow intensity based on the task at hand. This model is particularly well-suited for construction sites, manufacturing facilities, and emergency response applications.

Overall, Allegro Industries’ range of ventilation systems exemplifies cutting-edge engineering, providing effective air movement solutions for diverse industrial applications. Each model showcases a combination of technology, portability, and user-focused features, reinforcing Allegro's commitment to enhancing workplace safety and productivity.