Allegro Industries 9846, 9832, 9821 E R ’ S I N S T R U C T I O N S, Pressure Relief Valve RPV

Page 5

U S E R ’ S I N S T R U C T I O N S

1)Ensure that the pump (or inlet extension filter) is in a clean uncontaminated air environment.

o If clean air CANNOT be guaranteed at the pump inlet at all times, use the Inlet extension hose kit (P/N: 9700-65). See instructions on the Inlet extension kit below.

2)Ensure canister on the discharge filter assembly is firmly seated and secure before startup.

o Discharge air passes through the HEPA outlet filter located inside the discharged filter assembly. o HEPA filter is NOT for use as protection against vapors and gases.

o D.O.P. efficiency: 99.97% (0.3-0.6 micron particles)

3)Attach respirator/hood and air breathing hose to pump.

o Check respirator manufacturers’ recommendation for inspection/operation procedures. o Never start pump without hose and respirator attached.

o This may result in excessive back pressure that will lead to pump damage.

4)Ensure that air hoses are not tightly coiled or kinked.

o This may cause some restriction of the air flow causing the pump to run at a higher PSI and overheat.

5)Plug the pump into proper electrical outlet and turn on the power switch.

6)Properly adjust pressure relief valve. (see instructions for PRV below)

o Pumps are designed for multiple users and may require an adjustment to the pressure relief valve to fit the number of workers using the system.

7)Don the respirator as instructed per manufacturer user’s instructions.

8)Ensure all users are receiving sufficient air to the respirator.

o Use Allegro P/N 9900-40 “Flow test kit” to verify proper airflow (CFM) to the respirator.

o Ambient air pump gauge indicates the dynamic air pressure (back pressure), NOT air volume.

9)Enter work/contaminated area.

PRESSURE RELIEF VALVE (RPV):

1)Before making any adjustments check with the respirator manufacturer for the required CFM to that specific respirator.

2)To adjust the relief valve, loosen the lock nut.

3)Turn the adjustment knob counterclockwise to "bleed-off" air. o This will decrease pump output to the respirators.

o It is important to set the proper air flow to the respirator, too much air will over work the pump motor, causing it to overheat. Too little air will not provide sufficient air to the user.

4)Turn the adjustment knob clockwise to decrease air being bled off. o This will increase the pressure and air flow to respirators.

o Care must be taken to ensure that the respirator and air hose are not disconnected while pump is running, when the PRV is set to this setting. Pump damage will occur.

5)Tighten lock nut.

o PRV must be readjusted each time the number of users, respirator type or length of air hose is changed.

INLET EXTENSION KIT: (P/N 9700-65)

1)Locate the inlet filter where breathing air CANNOT be contaminated by harmful vapors, gases, or particulate and where it will be protected from excessive moisture.

o Inlet hose extensions may be used to increase distance from the inlet filter to the pump up to 250 feet. o With the use of remote Inlet Extension Hose(s), noise level at the pump is greatly reduced.

o The noise will be transferred by the hose to wherever the Inlet Filter is located.

o Respirators must be supplied with clean breathable air at all times, per OSHA 29CFR 1910.134.

2)In order to achieve this requirement, it may be necessary to use the inlet extension to reach a clean air environment.

3)Remove the inlet filter assembly from the pump.

4)Install inlet extension hose to the pump inlet port, using the supplied reducers/ adapters.

5)Install the inlet filter assembly on the other end of the extension hose.

o The A300 pump will require an inlet filter assembly (P/N: 9700-08) for use with the extension hose.

6)Place the extension hose in a clean, uncontaminated environment.

3

Image 5
Contents Allegro Number Table of ContentsINTRODUCTION/DESCRIPTION Tolerances and WarningsDescription IntroductionA. Grade-D Air Requirements AIR Driven Pump P/NInlet Extension KIT P/N E R ’ S I N S T R U C T I O N SPressure Relief Valve RPV Explosion Proof Pump L E R a N C E S a N D W a R N I N G SAIR Pump S P E C T I O N ALL Pumps Specification SElectrical Motors AIR Driven MotorsAIR Driven Motor P/N I N T E N a N C E FiltersFlushing Instructions Model A-300 R T S & a C C E S S O R I E S All ModelsModels A-750, A-750TE Models A-1500TE, A-1500EX, A-4000ADIf motor fails Troubleshooting Electric ModelsIf output air hot or pump is running hot If there is a rise in outlet pressureAIR Driven Pump If there is a drop in outlet pressureIf low torque or speed, or motor runs hot If motor won’t turn at allReturn Policy WarrantyLimitation of Liability Ambairpumman.doc Rev C /03

9832, 9806, 9850, 9833, 9846 specifications

Allegro Industries is a renowned manufacturer, specializing in a range of high-performance portable ventilation systems that cater to various industrial needs and environments. Among their celebrated offerings are the models 9821, 9846, 9833, 9850, and 9806, each designed with unique features that enhance productivity and safety in the workplace.

The model 9821 stands out due to its lightweight portable design, making it ideal for use in confined spaces or remote locations. This model boasts a powerful motor that generates a high volume of air movement, ensuring a steady flow of fresh air even in the most challenging environments. Additionally, it incorporates a rechargeable battery option, providing convenience and flexibility for users without direct access to power sources.

In contrast, the Allegro 9846 model is engineered for heavy-duty applications. It is equipped with a robust construction that can withstand the rigors of industrial workloads. Its high-efficiency fan system is designed to deliver maximum airflow while consuming minimal energy. This model is particularly effective in large spaces where effective ventilation is essential for maintaining air quality and worker safety.

The 9833 model takes a different approach by integrating advanced filtration technologies. This model includes a multi-stage filtration system that effectively captures dust, pollutants, and other airborne particles, making it suitable for environments that require clean air standards. The compact design allows easy transport and setup, ensuring it can be deployed swiftly when needed.

Model 9850 is designed for versatility, featuring a modular design that allows users to customize airflow parameters according to their specific requirements. With dual fan capabilities and the option for daisy chaining multiple units, this model is perfect for both small and expansive operations. Its intuitive controls make it user-friendly, allowing operators to adjust settings quickly while ensuring optimal performance.

Lastly, the 9806 model emphasizes durability, featuring a rugged casing that protects internal components from damage in harsh industrial settings. It offers adjustable speed settings, allowing users to tailor airflow intensity based on the task at hand. This model is particularly well-suited for construction sites, manufacturing facilities, and emergency response applications.

Overall, Allegro Industries’ range of ventilation systems exemplifies cutting-edge engineering, providing effective air movement solutions for diverse industrial applications. Each model showcases a combination of technology, portability, and user-focused features, reinforcing Allegro's commitment to enhancing workplace safety and productivity.