Toshiba EM1-31076, SL-9000N-FFH-CA, SL-9000N-FFH-US KEY Layout, Programming Keyboard Function

Page 13

5.KEY LAYOUT

5.1 PROGRAMMING KEYBOARD

5. KEY LAYOUT

5.1 PROGRAMMING KEYBOARD

NOTE: Blank keys have no function.

Programming Keyboard Function

Name of Key

Function

 

 

 

 

 

 

 

 

 

 

 

1. Clears numeric data just entered.

 

CLEAR

 

 

 

2. Releases the scale from the error mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selects the upper case or lower case.

 

SHIFT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calls the PLU # which follows the PLU # currently called.

 

SET

 

 

 

 

 

NEXT

 

Sets the media transparency on the sensor.

 

 

 

 

 

 

 

 

 

 

 

Calls the PLU # registered right after currently called PLU #.

 

NEXT

 

 

 

 

 

PLU

 

 

 

 

 

 

 

 

 

 

 

 

 

Sets “AUTO CODE”.

 

AUTO

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

Changes the PLU # currently called.

 

CHANGE

 

 

 

 

 

PLU

 

 

 

 

 

 

 

 

 

 

 

 

 

Deletes PLU.

 

DELETE

 

 

PLU

 

 

 

 

 

 

 

 

 

 

 

 

 

Prints data set in the currently called PLU.

 

TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inputs data to the SL-9000 system during programming.

 

ENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays the preceding PLU data. (only when changing the unit price)

 

VOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPT/

 

 

 

Inputs data to the SL-9000 system during programming. (only when changing the unit

 

*

 

 

 

 

 

price)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Returns to the main menu.

 

ESC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5- 1

Image 13
Contents SL-9000/9000N-FFH-US/CA/QR Page Table of Contents 12.2 12.113.1 13.2Page Introduction Applicable Model Accessories9 0 0 Scale SpecificationOption Appearance US Type DisplayFront Display Panel Rear Display PanelCA/QR Type Programming Keyboard KEY LayoutProgramming Keyboard Function Send SpaceProg Operation Keyboard Function Operation Keyboard and Speed KeyboardESC VoidLogo FeedSpeed KEY SET Procedure Before OperationScale installation on the wall or ceiling Installation ProcedurePlatter Removal and Replacement of RECEIPT/LABEL Removal and Replacement of RECEIPT/LABEL Outline of Operation How to access to Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditFor the UPC# PLU Data SettingKey advances to the next menu. Pressing the ↑ Ingredient Message Nutrition Setting Pressing the ↓ key instead Returns to the preceding menu Set the Daily Value Table Daily Value Max digits Contents of Daily valueDeleting Nutrition Data Memory file is sorted when a memory full error occursMemory file sort Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Call Thank YOU ANK YOU Call AGAESC Menu Special InformationSetting Department/Vendor Number Speed KEY SettingDepartment Number Vendor NumberBy pressing Key Print FormatFormat No Label Format Number TableMenu Item No DATE/TIME SettingCMT Operations PL-3 Operation Error code during PL-3Item # Transmission Item ListCMT IN-LINE/LOCAL Transmission Delay Time TableLON System Data Transmission Cancel Retry ContinuePrice Address SL-9000N only Initial #0-19, SL-9000N onlyBAR Code Format Default Bar Code Format① Weigh or Fix Price Format ② By Count FormatPLU # UPC # Flag PLU # UPC # PC/D Price WeightPLU # UPC # PC/D Additional 231 232 Title No Format Additional 221Additional 233 Additional 234 235 Additional 7,8 238 Additional 9,10 239SL-9000N only Transferring Logo DataVerify SL-9000=CMT Error message during data transmission Idiom SettingVendor Setting Key functions Free Format SettingEnter SP-INFO/NET WT ① Logo Print coordinate Programmed Data Verification Reports How to access Report menuSet the zone PLU #. Ex. PLU #100 to Setting Password and Protect Menu Password SecurityR S R S X Z× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresPower Weighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation for US Type only By Count Operation For Print Count Operation Example B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight Statement for US Type onlySample label 13-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Label Issue Stop or Cancel Dpt # Visual Commodity LibraryApple Floating VendorUNIT/$ Total $ Subtotal Price deletionTotal Operation How to access Report or Reset menuGrand Total Report Hourly Total ReportPLU Total Report Ex. Report MenuEntire PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service Troubleshooting

SL-9000N-FFH-QR, SL-9000N-FFH-US, SL-9000-FFH-CA, EM1-31076, SL-9000-FFH-US specifications

The Toshiba SL-9000 series, including models SL-9000-FFH-QR, SL-9000-FFH-US, SL-9000N-FFH-CA, EM1-31076, and EM1-31076EE, represents a significant advancement in modern technology, particularly in the field of home appliances and electronics. These models are designed with an emphasis on efficiency, user convenience, and innovative features that enhance functionality.

A standout feature across the SL-9000 series is its energy efficiency, which is achieved through advanced engineering and cutting-edge materials. This makes these models environmentally friendly while also reducing operational costs for users. The integrated technologies ensure that the devices operate at optimal performance levels even under demanding conditions.

The SL-9000-FFH-QR and SL-9000-FFH-US offer state-of-the-art connectivity options, allowing seamless integration with smart home systems. Users can control these appliances remotely through mobile applications or voice commands, contributing to a more convenient and customizable experience. The intuitive user interface is designed for ease of use, making it accessible for all age groups.

Another noteworthy characteristic is the superior build quality of these models. Toshiba employs robust materials that ensure durability and longevity, promising reliability over years of use. This attention to material quality also aligns with the aesthetic appeal of the devices, making them a stylish addition to any home environment.

The SL-9000N-FFH-CA features enhanced smart technologies, including real-time monitoring systems that provide users with valuable data on energy consumption and performance metrics. This information allows for informed decision-making regarding usage patterns and energy-saving practices.

The EM1-31076 and EM1-31076EE models focus on user-centric design, featuring adjustable settings that cater to individual preferences. This customization capability enhances the overall user experience, ensuring that each appliance meets unique needs effectively.

Overall, the Toshiba SL-9000 series combines innovative technology, energy efficiency, and user-friendly design to create appliances that not only perform exceptionally well but also integrate seamlessly into modern lifestyles. With these features and characteristics, Toshiba continues to set a high standard in the competitive landscape of home technology.