3. Step onto the Measurement Platform.
Make sure you are barefoot and the soles of your feet are clean and dry.
Position your feet on the electrodes as shown in the illustration to the right. Make sure each of your heels is positioned on a heel electrode.
Stand with your weight evenly distributed on the measurement platform. Remain still and do not move until the measurement is complete.
Heel Electrodes
Your weight will appear, then blink on the display. The indicators in the
measurement progress bar at the bottom of the display will begin to appear from left to right.
When the measurement is completed, your weight is displayed again.
4. Step off the Measurement Platform.
The measurement results are automatically displayed repeatedly in the following order:
WEIGHT [ %FAT [ BMI.Display
Weight: 0.0 lb to 330.0 lbs in 0.2lb increments
Body fat percentage: 5.0 to 60.0% in 0.1% increments
BMI: 7.0 to 90.0 in 0.1 increments
BMI Classification
Body Fat Percentage Classification
NOTE: Although the age range can be set between 10 and 80 years, the % FAT classification will only display if the age is set between 20 and 79 years.
14
Immerse your feet in warm water or stay in a warm room to allow your feet to warm up.
Your body and feet are cold due to poor blood circulation.
Leave the unit in a warm room for approximately 10 minutes to allow the electrodes to warm up.
Feet are too dry.
When you step onto the electrodes, the electrodes feel too cold.
Action
Slightly moisten the soles of your feet with a wet towel before taking a measurement.
Condition
HOW TO TAKE A MEASUREMENT
NOTE: If the soles of your feet are too dry, the temperature of your feet or the electrodes are extreme cold, it will not be possible to obtain stable measurements. These conditions may cause an error indicator to display or inaccurate results. Be aware of these conditions during colder months when the air is dry and/or the temperature is low.
Image 14
Contents Fat Loss Monitor With Scale Table of Contents Introduction Date Purchased Serial NumberImportant Safety Notes What is the DXA method? What is the Bioelectrical Impedance Method?How to estimate the body fat percentage Useful InformationRecommended Measurement Times 40-59 HOW to Interpret Calculated ResultsFemale 20-39 60-79Know Your Unit Main UnitBattery Installation Battery ReplacementPress the SET button Setting Personal DataTurn the monitor on GuestPress the SET button. The age is set Enter your Personal DataPress the UP button or Down button to Change the age Press the UP button or Down button to change the genderPress the User button Adjust the settings you need to changeChanging Personal Data Press the SET button againHOW to Take a Measurement When to avoid taking a measurementPage Step onto the Measurement Platform Turn the monitor off. Press the Power SwitchViewing Measurement Results Step off the Measurement Platform Turn the monitor offError Indicators Error Display Cause CorrectionProblem Cause and Solution Troubleshooting TipsCare and Maintenance Press the SET button Step onto the Measurement Platform Quick Reference GuidePress the GUEST/MEMORY button Step off the measurement PlatformFCC Statement Warranty Information Limited WarrantySpecifications Track Your Progress Page Omron HEALTHCARE, INC