Braun BP3560, BP3550 manual Product description, Inserting batteries

Page 6

Product description

APositioning system

BConfirmation system

COn/off button

DSelect button

EMemory button («memo»)

FCuff closure

GRelease button

HBattery compartment

IDistance aid

6

 

0

 

R

 

L

3

 

0

 

R

 

L

Inserting batteries

Use alkaline batteries, type LR 03 (AAA) (e.g. Duracell) as supplied with this product (or rechargeable batteries).

Remove the battery compartment cover and insert two batteries with correct polarity (see symbol in the battery compartment (H)).

New batteries (Duracell) will provide approximately 300 measurements.

Only discard empty batteries. They should not be disposed of in the household waste, but at appropriate collection sites or at your dealer.

Key rules for accurate blood pressure measurements

Correct handling is key for obtaining accurate measuring results!

Always take readings at the same time of day, ideally in the morning, under the same conditions.

Do not measure within 30 minutes after smoking, coffee or tea consumption.

Take off wristwatch and jewelry before fitting the appliance on the measuring arm.

Position the monitor 2 cm below the palm line.

While taking a measurement, sit down, relax, keep still, especially the hand and fingers of the measuring arm, do not move or speak.

Hold the appliance at heart level during the measurement.

Wait approximately 3 minutes before repeating a measurement.

6

Image 6
Contents SensorControl liClick Braun Infolines Easy Click What you should know about blood pressure What you should know about this blood pressure monitor Product description Inserting batteriesKey rules for accurate blood pressure measurements Measuring Press the red on/off button CPage Memory mode Turning offRecalling stored readings Deactivating the positioning system a Select modeSetting date and time Please noteStorage and cleaning CalibrationProblem Reason Solution What to do ifSpecifications Guarantee For UK onlyTansiyon hakk∂nda bilmeniz gerekenler Bu tansiyon ölçer hakk∂nda bilmeniz gerekenler Ürün tan∂m∂ Pilleri yerleµtirmeDoπru ölçüm için önemli kurallar Ölçüm iµlemi Lütfen dikkat edin Kapatma Haf∂zaHafızadaki ölçümleri görmek için Seçim select modu Tarih ve zaman ayar∂Lütfen dikkate al∂n Saklama ve temizleme Herhangi bir problem söz konusuysa ne yap∂lmal∂d∂r?Problem Sebep Çözüm AyarlamaÖzellikler Güç kaynaπ∂ ÓÚÓ Ç˚ ‰ÓÎÊÌ˚ Á̇ڸ Ó ÍÓ‚flÌÓÏ ‰‡‚ÎÂÌËË DIAÓÚÓ Ç˚ ‰ÓÎÊÌ˚ Á̇ڸ Ó ‰‡ÌÌÓÏ ÔË·Ó ‰Îfl ËÁÏÂÂÌËfl ‰‡‚ÎÂÌËfl ÉÔËÒ‡ÌË ÔË·Ó‡ ÌÒÚ‡Ìӂ͇ ·‡Ú‡ÂÂÍÉÒÌÓ‚Ì˚ Ô‡‚Ë· ÚÓ˜ÌÓ„Ó ËÁÏÂÂÌËfl ÍÓ‚flÌÓ„Ó ‰‡‚ÎÂÌËfl ÀÁÏÂÂÌË ÍÓ‚flÌÓ„Ó ‰‡‚ÎÂÌËfl ‡ÊÌÓ ˚Íβ˜ÂÌË ÎÛÌ͈Ëfl Ô‡ÏflÚˇÒÚÓÈÍË ÌÒÚ‡Ìӂ͇ ‰‡Ú˚ Ë ‚ÂÏÂÌË‡ÌÂÌËÂ Ë ˜ËÒÚ͇ ‡ÎË·ӂ͇ÓÚÓ ‰Â·ڸ Âòîë ‡ÌÊÂÚ˚ Ë ËÔˆËÙË͇ˆËfl BP 3560 / BP‡‡ÌÚËÈÌ˚ ӷflÁ‡ÚÂθÒÚ‚‡ ÙËÏ˚ Braun ËÎÛ˜‡Ë, ̇ ÍÓÚÓ˚ „‡‡ÌÚËfl Ì ‡ÒÔÓÒÚ‡ÌflÂÚÒfl Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page SYS 20 cm Page Distance 2 cm Memo Page Page Page Page Page Page 0297 Page     Page Measuring Ölçüm iµlemi ÀÁÏÂÂÌË ÍÓ‚flÌÓ„Ó ‰‡‚ÎÂÌËfl Page Page Example Örnek