Troubleshooting Diagnosis Chart
FUNCTION |
| POSSIBLE CAUSE | REMEDY |
|
|
|
|
| 4.11 | Outer Barrier switch is out of | Check diagnostic LCD for Outer Barrier switch sta- |
4.00 |
| adjustment or defective. | tus. Barrier is down or barrier release pin partially |
LIFT WILL |
|
| out. Adjust or replace switch as necessary. |
GO UP WITH | 4.12 | Full Out switch is not activated or |
|
OVERRIDE | Check diagnostic LCD for Full Out switch status. | ||
SWITCH BUT |
| defective. | Adjust or replace switch as necessary. |
NOT WITH |
|
|
|
4.13 | Check for | ||
PENDANT |
| properly. | tinuity of the switches. Verify SW1 and Door Open |
|
|
| switches are functioning correctly. |
|
|
|
|
|
|
|
|
5.00 | 5.11 | Hydraulic Down valve bad | Check for power on red “valve” wire from P.C. |
LIFT WILL | |||
NOT GO |
|
| board to Down solenoid when pushing override |
DOWN WITH |
|
| switch or |
OVERRIDE |
|
| necessary. |
SWITCH |
|
|
|
OR WITH | 5.12 | Dirty Down valve (clogged) | Flush valve by operating Up and Down manual |
|
| override switches at same time for 4 to 5 seconds | |
PENDANT, |
|
| |
|
| several times. | |
GOES DOWN |
|
| |
|
|
| |
SLOWLY OR |
|
|
|
LIFT DRIFTS |
|
|
|
DOWN BY |
|
|
|
ITSELF |
|
|
|
|
|
|
|
|
|
|
|
6.00 |
|
| Check diagnostic LCD for Full Out switch status. |
LIFT WILL GO | 6.11 | Full Out switch out of adjustment or | |
DOWN WITH |
| defective. | Adjust or replace switch as necessary. |
OVERRIDE |
|
|
|
SWITCH BUT | 6.12 | SW0 and/or Door Full Close switch- | Check switches for proper operation/adjustment. |
NOT WITH |
| es out of adjustment or defective. | Adjust or replace switch as necessary. |
|
|
| |
PENDANT |
|
|
|
|
|
|
|
7.00 |
|
|
|
LIFT WILL NOT | 7.11 Poor plug connections | Check harness connections A1, A2, B1 and B2 | |
EXTEND WITH |
|
|
|
OVERRIDE | 7.12 | Bad In/Out motor | Check power at motor. Replace motor if necessary. |
SWITCH OR |
|
|
|
7.13 Bad power and ground | See 1.00 | ||
PENDANT |
|
|
|
|
|
|
|
|
|
|
|
| 8.11 | Stow Level switch out of adjust- | Check diagnostic LCD for Stow Level switch sta- |
|
| ment or defective. | tus. Adjust or replace switch as necessary. |
8.00 | 8.12 | Platform is occupied or out of | Remove weight from platform. See Platform |
LIFT WILL NOT |
| calibration | Sense Calibration on page 5. |
STOW WITH | 8.13 | SW0 and/or Door Full Closed | Check switches for proper operation/adjustment. |
PENDANT |
| switches out of adjustment or | Adjust or replace switch as necessary. |
|
| defective. |
|
| 8.14 | Handrail Belt | Belt must be latched until platform is at stow level |
|
|
| and must be unlatched before platform will stow. |
|
|
|
|
Page 17