Floor Level and Inner Roll Stop Adjustments
Inner Roll Stop Adjustment
3.Use an Allen wrench to prevent the cam locking screw from turning and loosen the 3/8" ser- rated flange nut securing the lifting arm cam. See Photos D and E. Do not remove the screw or nut.
4.Raise the platform 1" above floor level using the manual operation system.
5.Turn the cam adjustment screw counterclockwise until the inner roll stop rests on the floor.
Do not continue to turn the adjustment screw once the inner roll stop is contacting the vehicle floor.
6.Verify there is no gap between the inner roll stop and the roll stop catch. See Photo F. Turn the adjustment screw clockwise to bring the roll stop catch back in contact with the inner roll stop. Do not remove the gap by adjusting the linkage rod.
7.While holding the cam locking screw, tighten the 3/8" serrated flange nut securely.
3/8"
Serrated
Flange Nut
Cam Locking Screw | D |
Cam Adjustment
Screw
E |
Inner
Roll Stop Roll Stop
Catch
Linkage Rod
F |
Page 9