Sentry Industries Sentry 2.0 operating instructions Multiple Zone Options

Page 21

Configuration Code (CFG)

Information for Technicians

From IdLE , press OPTIONSrepeatedly until CFG ap- pears. Press ENTER. The factory configuration code will ap- pear. Press ENTER. Press STOP to return to IdLE . The configuration code can be changed only at the factory.

Software Version (SOFT)

Information for Technicians

From IdLE , press OPTIONSrepeatedly until SOFT ap- pears. Press ENTER. The software version will appear. Press ENTER. Press STOP to return to IdLE . The software ver- sion can be changed only at the factory.

Element Test (TEST)

Test the Heating Elements and Relays

This test is useful when measuring the wall receptacle voltage under load, and amperage with an ammeter. On a multiple zone kiln, the test helps determine if the relays and thermocouples are wired to the correct zones. If you test thermocouples with a lighter or other heat source, use the Test option.

Single Zone Kiln

1From IdLE , press OPTIONSrepeatedly until TEST appears.

2Press ENTER. POWR will appear, alternating with kiln temperature. The elements will turn on for 2 minutes. Press any key to abort the test.

Multiple Zone Kiln

1From IdLE , press OPTIONSrepeatedly until TEST appears.

2Press ENTER. TOP will appear, alternating with the temperature of the top zone. The elements will

turn on for 2 minutes. Then MID will appear, with temperature for the middle zone, and BOT with temperature for the bottom zone. (A 2 zone kiln shows TOP and BOT displays only.)

3During the 2 minute test, press any key to end a zone test. The controller will then begin to test the next zone.

AOP Outlet

After the above tests, kilns equipped with the AOP outlet will display J3-3for 2 minutes to test power to the AOP outlet.

Reset (RST)

Reset the Controller to Most Factory Defaults: Perform Only When Requested by a Technician

Reset does the following:

Selects Type-S thermocouple

Selects °F

Erases Cone offsets

Erases Thermocouple offset

Erases user programs in Ramp-Hold

CAUTION: If your kiln uses a Type-K thermocou- ple, the Sentry will underfire after a reset! Use the Thermocouple Option (page 19) to select Type-K again.

1From IdLE , press OPTIONSrepeatedly until RST appears.

2 Press ENTER. Use the 1 or 2 key to select NO or YES .

3After selecting one of the above, press ENTER. Press STOP to return to IdLE .

Multiple Zone Options

These options appear only on multiple zone kilns.

Zone Temperature Difference (DIFF)

View Maximum Temperature Spread

For a 2 zone kiln, this option shows temperature differ- ence between the zones. For a 3 zone kiln, it shows the high- est temperature difference between any two zones. If the temperature shown is larger than expected, go to option T 123 to view the temperature of each zone.

1 Press OPTIONS repeatedly until DIFF appears. Press ENTER.

3The maximum difference in temperature between any zones displays. (Example: -003 .)

Two Zone Kilns: Adjust Heat in Center Section (CAdJ)

The Center Adjust option appears only on 2 zone kilns that contain 3 relays and 3 banks of elements. It does not ap- pear on 2 zone kilns with 2 relays, or on 3 zone. The Center Adjust acts as an infinite control switch that adjusts heat to the center section of the kiln. A number will display. 100 is the factory default, meaning 100% heat. You can change the setting from 0 to 200. The higher the number, the more the heat in the center section.

1From IdLE , press OPTIONSrepeatedly until CAdJ appears.

2Press ENTER. Use any number key to change the number that appears.

3Press ENTER. Press STOP to return to IdLE .

Zone Temperatures (T123)

View Temperature of Each Zone

1 Press OPTIONS repeatedly until T123 appears. Press ENTER.

3The temperature for each zone will display one after the other, cycling for one minute. Then normal tem- perature display will return. For example:

Top zone: TC 1¯ 1250

Middle zone:

TC 2-

 

1251

 

 

Bottom zone:

 

 

 

 

TC 3_

 

1249

 

21

Image 21
Contents Multiple Zone Options Standard OptionsIntroduction Contents Room Temperature and Humidity SafetyThunder Storms and Power Surges Basic PointersDisplay Lights How to Get IdLE to DisplayFiring Completion Message Repeat FiringsKeys Enter/Start Cone Numbers Skip SegmentOptions Key Stop/Back KeyCone-Fire How to Position Cones on the ShelfPyrometric Witness Cones Firing SchedulesCone-Fire Features Speed SPdPre-Heat Prht Cone-Fire Programming Hold HOLdMirror Test Slow Cooling Cool When the Kiln Shuts Off Too SoonFor Kilns with AOP Outlet Wrong Thermocouple TypeDefinition of a Segment Ramp-HoldUser Programs User Ramp-Hold ProgrammingRate Firing a Stored User ProgramAOP Fan Segments for Controlled CoolingStarting a Firing in a Hot Kiln Glass Fusing Firing ScheduleGlass Slumping Firing Schedule Ceramic FiringsMultiple Zone Kilns Cone-Fire Options OptionsCone-Fire Speed Spd Cone Offset OfstGeneral Options Fan FANThermocouple Offset Tcos Thermocouple Type TC Selecting F or C CHGMaximum Temperature Sfty Temperature Deviation TedeElectronics Temperature Elec AOP Outlet AOPMultiple Zone Options Error Messages Non-Interrupting Error MessagesTerminating Error Messages Plog Error Codes How the Sentry Handles Power FailuresTCdE / Uneven Multiple Zone Temperatures TCR / Thermocouple Leads ReversedAppendix a Display Messages Diagnostic Test Failure Power FailureReset SafetyLow Fire Cones F SegmentCone Rate 1 Temp Rate 2 Temp Low Fire Cones C Appendix B Preset Standard Cone-Fire Schedules CUpgrading the DTC 100, 600, 800 & 1000 to the Sentry Appendix C Upgrading InstructionsPage 022 Cone Self-Supporting Cones Pre-Fire Number Color010 05 1/2Appendix E Sentry Ramp-Hold Shorthand InstructionsKiln is now firing. Use Program Review by pressing Appendix F Sentry Cone-Fire Shorthand ProgrammingKiln is now firing to the cone you selected

Sentry 2.0 specifications

Sentry Industries has recently unveiled the Sentry 2.0, an innovative enhancement to their line of security solutions. This state-of-the-art platform is designed to address modern security challenges with a blend of advanced technology and user-centric features.

One of the standout features of Sentry 2.0 is its integrated artificial intelligence capabilities. The system employs machine learning algorithms to analyze behavior patterns, allowing for real-time threat detection and response. This proactive approach means that potential security breaches can be identified and mitigated before they escalate, significantly reducing risk for businesses and individuals alike.

In addition to its AI-driven technology, Sentry 2.0 boasts an intuitive user interface that simplifies the management of security systems. This user-friendly design enables users, regardless of their technical know-how, to configure and monitor security settings effortlessly. The dashboard provides a comprehensive overview of the security landscape, displaying real-time data, alerts, and system status updates in a clear and accessible manner.

Another notable characteristic of Sentry 2.0 is its robust integration capabilities. The platform can seamlessly connect with various security devices, including cameras, motion sensors, and access control systems, creating a unified security ecosystem. This interoperability ensures that users can easily expand or customize their security solutions as their needs change over time.

Sentry 2.0 also prioritizes data privacy and protection. With end-to-end encryption and secure cloud storage, users can trust that their sensitive information is safeguarded against unauthorized access. The platform complies with industry standards and regulations, offering peace of mind in an increasingly digital landscape.

Moreover, Sentry 2.0 includes advanced reporting features, enabling users to generate insights from their security data. These analytics can help organizations understand trends, optimize response strategies, and ultimately enhance their overall security posture. The ability to generate customized reports empowers businesses to make informed decisions based on detailed analyses of their security systems.

In summary, Sentry Industries has positioned the Sentry 2.0 as a cutting-edge solution in the realm of security technology. With its AI capabilities, user-friendly interface, integration versatility, data protection measures, and advanced reporting, Sentry 2.0 addresses the diverse needs of today's security landscape, setting a new standard for security solutions.