Sentry Industries Sentry 2.0 operating instructions Standard Options, Multiple Zone Options

Page 1

Sentry 2.0

Digital Temperature Controller

Complete Operating Instructions

See pages 28-29 for instructions on upgrading your DTC

100, 600, 800 or 1000 series board to the Sentry.

Cone-Fire (pg 8-11)

From IdLE, press 1.

Available only on ceramic kilns. Fires to a pyrometric cone. Enter cone, speed, pre-heat, hold, and slow cool.

Ramp-Hold (pg 12-15)

From IdLE, press 4.

Select stored program (1 - 4). Enter rate, temperature, and hold for each segment.

Alarm (pg 6)

From IdLE or during firing, press 7.

Enter a temperature. When alarm sounds during firing, press Enter.

Enter/Start (pg 7)

Press Enter/Start after each step in programming a firing. Press Enter/Start once to be- gin the firing.

Delay (pg 6)

From IdLE, press 3.

Enter time in hours:minutes. Delays the start of firing.

Add Time (pg 6)

During firing, press 2.

Each additional key press adds five minutes to a hold. It works in both Ramp-Hold and Cone-Fire.

Present Status (pg 6)

Press 5 during firing.

Shows the segment that is currently firing. Works in both Ramp-Hold and Cone-Fire.

Program Review (pg 6)

From IdLE or during firing, press 6.

Shows the program that is loaded in memory and ready to fire, or the one that is firing.

Options (pg 17 - 21)

From IdLE, press 0. Press Enter for option displayed. Cone-Fire Options

SPd Speed Change the speed of a Cone-Fire program beyond the Fast, Medium, or Slow.

OFST Cone Offset Adjust con- troller to a witness cone.

FAN Vent Fan Selects when the vent fan will operate. (Special

Id Computer ID Select identi- fication number for output to a computer.

TEdE Temperature Deviation Set temperature sensitivity of er- ror codes.

SFTY Maximum temp.

ELEC Electronics Temp. Check board for overheating.

LOCK Program Lock Make a

Stop/Back (pg 7)

Press during firing or programming.

Stops a firing. In Options, takes you back to IdLE. During programming, takes you back one step each time key is pressed.

Cone Table & Skip Segment (pg 7)

From IdLE or during firing, press 9.

From IdLE, shows tempera- ture for the cone you enter. While Firing: In Ramp-Hold, skips to the next ramp. In Cone-Fire, skips out of Pre-Heat or Hold.

option not on all kilns.)

Standard Options

TCOS Thermocouple Offset Calibrate the thermocouple temperature.

CHG- Select °F or °C.

TC Thermocouple Type Se- lect Type K, S or R.

AOP AOP Outlet Select vent fan or alarm. This is a special op- tion not on all kilns.

program tamper-proof.

CFG Configuration Code For technicians.

SOFT Software Version For technicians.

TEST Element Test Diagnos- tics tool for checking elements.

RST Reset Removes cone and thermocouple offsets, etc.

Multiple Zone Options

DIFF Difference Largest temperature difference be- tween any two zones.

CAdJ Center Adjustment Change center heat of some two-zone kilns.

T123 Zone Tempera- tures Shows temperature of each zone.

1

Image 1
Contents Multiple Zone Options Standard OptionsIntroduction Contents Room Temperature and Humidity SafetyThunder Storms and Power Surges Basic PointersDisplay Lights How to Get IdLE to DisplayFiring Completion Message Repeat FiringsKeys Enter/Start Cone Numbers Skip SegmentOptions Key Stop/Back KeyCone-Fire How to Position Cones on the ShelfPyrometric Witness Cones Firing SchedulesSpeed SPd Cone-Fire FeaturesPre-Heat Prht Hold HOLd Cone-Fire ProgrammingMirror Test Slow Cooling Cool When the Kiln Shuts Off Too SoonFor Kilns with AOP Outlet Wrong Thermocouple TypeDefinition of a Segment Ramp-HoldUser Programs User Ramp-Hold ProgrammingRate Firing a Stored User ProgramAOP Fan Segments for Controlled CoolingStarting a Firing in a Hot Kiln Glass Fusing Firing ScheduleGlass Slumping Firing Schedule Ceramic FiringsMultiple Zone Kilns Cone-Fire Options OptionsCone-Fire Speed Spd Cone Offset OfstFan FAN General OptionsThermocouple Offset Tcos Thermocouple Type TC Selecting F or C CHGMaximum Temperature Sfty Temperature Deviation TedeElectronics Temperature Elec AOP Outlet AOPMultiple Zone Options Non-Interrupting Error Messages Error MessagesTerminating Error Messages Plog Error Codes How the Sentry Handles Power FailuresTCdE / Uneven Multiple Zone Temperatures TCR / Thermocouple Leads ReversedAppendix a Display Messages Diagnostic Test Failure Power FailureReset SafetySegment Low Fire Cones FCone Rate 1 Temp Rate 2 Temp Low Fire Cones C Appendix B Preset Standard Cone-Fire Schedules CUpgrading the DTC 100, 600, 800 & 1000 to the Sentry Appendix C Upgrading InstructionsPage 022 Cone Self-Supporting Cones Pre-Fire Number Color010 05 1/2Sentry Ramp-Hold Shorthand Instructions Appendix EKiln is now firing. Use Program Review by pressing Sentry Cone-Fire Shorthand Programming Appendix FKiln is now firing to the cone you selected

Sentry 2.0 specifications

Sentry Industries has recently unveiled the Sentry 2.0, an innovative enhancement to their line of security solutions. This state-of-the-art platform is designed to address modern security challenges with a blend of advanced technology and user-centric features.

One of the standout features of Sentry 2.0 is its integrated artificial intelligence capabilities. The system employs machine learning algorithms to analyze behavior patterns, allowing for real-time threat detection and response. This proactive approach means that potential security breaches can be identified and mitigated before they escalate, significantly reducing risk for businesses and individuals alike.

In addition to its AI-driven technology, Sentry 2.0 boasts an intuitive user interface that simplifies the management of security systems. This user-friendly design enables users, regardless of their technical know-how, to configure and monitor security settings effortlessly. The dashboard provides a comprehensive overview of the security landscape, displaying real-time data, alerts, and system status updates in a clear and accessible manner.

Another notable characteristic of Sentry 2.0 is its robust integration capabilities. The platform can seamlessly connect with various security devices, including cameras, motion sensors, and access control systems, creating a unified security ecosystem. This interoperability ensures that users can easily expand or customize their security solutions as their needs change over time.

Sentry 2.0 also prioritizes data privacy and protection. With end-to-end encryption and secure cloud storage, users can trust that their sensitive information is safeguarded against unauthorized access. The platform complies with industry standards and regulations, offering peace of mind in an increasingly digital landscape.

Moreover, Sentry 2.0 includes advanced reporting features, enabling users to generate insights from their security data. These analytics can help organizations understand trends, optimize response strategies, and ultimately enhance their overall security posture. The ability to generate customized reports empowers businesses to make informed decisions based on detailed analyses of their security systems.

In summary, Sentry Industries has positioned the Sentry 2.0 as a cutting-edge solution in the realm of security technology. With its AI capabilities, user-friendly interface, integration versatility, data protection measures, and advanced reporting, Sentry 2.0 addresses the diverse needs of today's security landscape, setting a new standard for security solutions.