Axor 06453XX0, 6405000, 06455XX0, 06452XX0 Technical Specification, Installation Considerations

Page 3

04172XX0

04185XX0

04198XX0

Technical Specification

Recommended pressure

45 - 72 psi

Maximum hot water temp.

165° F*

Recommended hot water temp.

120° - 140° F*

Flow rate @ 44 PSI

8 gpm

Safety stop

100° F

1/2" female NPT inlets

 

Maximum mounting surface thickness

1 3/8"

Hole size in mounting surface

2 3/8"

*Know and follow all applicable local plumbing codes when setting the temperature on the water heater.

Installation Considerations

For best results, Hansgrohe recommends that this unit be installed by a licensed, profes- sional plumber.

Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation.

The mounting surface must be installed and made watertight prior to installation.

For best service of the ThermoBalance valve, the pressure of the incoming hot water and the pressure of the incoming cold water must be equal.

This valve is for a two-function installation. Both outlets must be plumbed. If only one function is to be used, loop the two outlets together. Do not plug either outlet.

Some areas have plumbing codes limiting the maximum output temperature. The high temperature limit stop may be reset to comply with these codes. See page 7.

Image 3
Contents Installation Instructions / Warranty 06450XX0 Installation Considerations Technical SpecificationInstall the rough Install the outlet lines Install the hot and cold water supply linesJustify the handle Install the valve trimSet the high temperature limit stop optional Maintenance Clean the filters User instructions Replacement parts Limited Lifetime Consumer Warranty Cleaning Recommendation for Hansgrohe ProductsThis Warranty does not COVER, and Hansgrohe will not PAY for