04172XX0 | 04185XX0 | 04198XX0 |
Technical Specification
Recommended pressure | 45 - 72 psi |
Maximum hot water temp. | 165° F* |
Recommended hot water temp. | 120° - 140° F* |
Flow rate @ 44 PSI | 8 gpm |
Safety stop | 100° F |
1/2" female NPT inlets |
|
Maximum mounting surface thickness | 1 3/8" |
Hole size in mounting surface | 2 3/8" |
*Know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation Considerations
•For best results, Hansgrohe recommends that this unit be installed by a licensed, profes- sional plumber.
•Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation.
•The mounting surface must be installed and made watertight prior to installation.
•For best service of the ThermoBalance valve, the pressure of the incoming hot water and the pressure of the incoming cold water must be equal.
•This valve is for a
•Some areas have plumbing codes limiting the maximum output temperature. The high temperature limit stop may be reset to comply with these codes. See page 7.