Install the valve trim

Remove the plaster shield.

Push the escutcheon over the valve.

Install the handle. Tighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge.

Justify the handle.

Set the high temperature limit stop, if required.

slot

Justify the handle

Turn the water on to the tub spout or hand- shower. Place a thermometer in the water stream. Turn the temperature control knob until the output water temperature is 100°F. Turn the water off.

Loosen the handle screw with a 3 mm Allen wrench. Remove the handle.

Image 6
Contents Installation Instructions / Warranty 06450XX0 Technical Specification Installation ConsiderationsInstall the rough Install the hot and cold water supply lines Install the outlet linesInstall the valve trim Justify the handleSet the high temperature limit stop optional Maintenance Clean the filters User instructions Replacement parts Cleaning Recommendation for Hansgrohe Products Limited Lifetime Consumer WarrantyThis Warranty does not COVER, and Hansgrohe will not PAY for