11
Make Gas Connection
If converting to Natural gas, see conversion kit requirements in
the “Gas Supply Requirements” section. Follow instructions
included with kit.
LP Gas:
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the grill must be used. Replacement gas pressure
regulator/hose assembly specific to your model, is available from
your outdoor grill dealer.
To Install the 20 lb LP Gas Fuel Tank:
1. Open the 20 lb LP gas fuel tank drawer.
2. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray
3. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
4. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown.
5. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
6. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
7. Go to “Check and Adjust the Burners” section.
If Converted to Natural Gas
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
grill to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the grill to the rigid gas supply
line. A ⁵⁄₈" diameter line is recommended. Using a wrench
to tighten, connect the gas supply to the grill. Use pipe-
joint compound on all non-flared male threads. Do not
kink or damage the flexible connector when moving the
grill.
A.Locking screw
B.Mounting hole
C.Bottom collar
WARNING
Explosion Hazard
Securely tighten all gas connections.

If connected to LP, have a qualified person make sure

gas pressure does not exceed 11” (28 cm) water

column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
BC
A.20 lb LP gas fuel tank
B.Gas pressure regulator/hose assembly
A
B
WARNING

Explosion Hazard

Use a new CSA International approved “outdoor”

gas supply line.

Securely tighten all gas connections.

Failure to do so can result in death, explosion, or fire.