JACKET INSTALLATION

Page 28

GB300 BOILER INSTALLATION AND OPERATION INSTRUCTIONS

When all of the burner tubes are in place adjust the manifold so the burner tube orifice brackets are positioned midway along the cylindrical portion of the orifice, Figure 65. Make sure all of the burner tubes are locked into the base rear panel as shown in Figure 64.

Figure 65

Burner Tube Placement on Orifice

WARNING: The burner tubes must be installed as described above. Make sure that the notch on each burner tube is locked into the rear burner base panel, Figure 64. Failure to properly install the burner tubes could result in a fire or explosion causing extensive property damage, severe personal injury or death!

JACKET INSTALLATION

Bolt the jacket brackets found in Box 63273 to the lower rear flange of the burner base side panels, Figure 66.

NOTE: Before installing the jacket, any nipples, steam risers or short pieces of pipe that will penetrate the jacket should be installed in the cast iron sections. Do not attach any fittings or other devices that would prevent the jacket panels from fitting over them.

NOTE: There are two jacket boxes for the 5 through 12 section models.The 13 through 21 section models will come with 4 jacket boxes.

Open the Box(s) that are marked with a number from 55177 to 55184, Jacket Less Sides, Figure 67, and remove the jacket rear panel(s).

Figure 67

Box 55177 to 55184, Jacket Less Sides

Figure 66

Rear Jacket Bracket Attachment