Smith Cast Iron Boilers GB300 warranty Figure, Burner Base Splice Panel Bracket, C, D

Models: GB300

1 52
Download 52 pages 14.03 Kb
Page 16
Image 16
Figure 22B

Page 16

GB300 BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Bolt the insulation splice panel bracket to the front base

Figure 22B

Burner Base Splice Insulation Boards

channel, Figure 21. Install the two insulation boards in

 

 

the spaces between the two front and two rear burner

 

 

base panels. Firmly but carefully press the insulation

 

 

boards in place and insert the nails through the top and

 

 

bottom holes, Figure 22A&B.

 

 

Orientate and install splice refractory retainer. Center the

 

 

retainer over the splice refractory and mating base

 

 

panels. The retainer should fit snuggly with the flat edge

 

 

on the outside of the base and the angled edge mating

 

 

flush to the refractory. Once insulation boards are

 

 

installed, slide the retention bracket over the top of the

 

 

base splice as shown in Figures 22C and 22D. Tighten

 

 

all bolts in base.

 

 

 

Figure 21

Burner Base Splice Panel Bracket

 

 

 

 

Figure 22C

 

Figure 22D

Figure 22A Burner Base Splice Insulation Boards

NOTE: Check all of the bolts in the base to ensure they are tight before removing the burner tubes and manifold.

Page 16
Image 16
Smith Cast Iron Boilers GB300 Figure, Burner Base Splice Panel Bracket, C, D, A Burner Base Splice Insulation Boards