Smith Cast Iron Boilers GB300 warranty Burner Base Assembly 5 through 12 Sections, Figure

Models: GB300

1 52
Download 52 pages 14.03 Kb
Page 12
Image 12
Burner Base Assembly 5 through 12 Sections

Page 12

GB300 BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Burner Base Assembly 5 through 12 Sections

Figure 8 Burner Base Rear Panel Detail, 5 - 12 Sect

Loosely attach the base baffle to the side panels using 4

 

5/16 stainless steel nuts. Install the burner base front,

 

side and rear panels as shown in Figures 6, 7, 8 and

 

9A.

 

 

Use a spirit level to ensure that the burner base panels

 

are plumb before tightening the stainless steel nuts and

 

bolts.

 

 

The factory installed refractory retention bracket(s) must

 

be centered on each piece of refractory board Figure

 

9B. If the bracket is not centered reposition bracket.

 

There is (1) bracket for each section of refractory.

 

Figure 6

Burner Base Side Panels, 5 - 12

 

Figure 9A Burner Base Rear Panel, 5 - 12 Sect

Figure 7

Burner Base Front Panel, 5 - 12 Sect

Figure 9B

Refractory Retension Bracket

Page 12
Image 12
Smith Cast Iron Boilers GB300 warranty Burner Base Assembly 5 through 12 Sections, Figure, Burner Base Side Panels, 5