Hold the handle lever in one hand. With the other hand, turn the tempera- ture control knob until the 100° mark is next to the indexing mark on the handle.
Install the handle on the valve. Tighten the screw.
Set the high temperature limit stop (optional)
Turn the water on to the tub spout or handshower. Use a 3 mm Allen wrench to loosen the handle screw. Remove the handle from the valve.
Carefully remove the retainer clip and the limit stop ring (1).
Turn the temperature control stem until the water is the desired high temperature, usually 110°F* (2). Turning the stem clockwise will make the water cooler, turning it
Install the stop ring so that it is against the stop
Install the handle. Tighten the screw. Justify the handle.
*Know and follow all applicble local plumbing codes when setting the high temperature limit stop. In Massachusetts, the maximum output temperature can be no higher than 112° F.
1 | 2 | 3 |