Wayne-Dalton 346918 Top Fixtures, Strut A-symmetrical, Drawbar Operator Bracket

Page 9
Bottom half of drawbar
operator bracket
Bottom rib

Lock section

(2) 1/4”-20 x 11/16”

(2) 1/4”-14 x 5/8”

(2) 1/4”-20 x 11/16”

Self drilling screws

Self tapping screws

Self drilling screws

(2) 1/4”-14 x 5/8”

Strut (A-symmetrical) End cap

Self tapping screws

(attached to top rib)

30” To 36”

 

 

Left double graduated

 

Vertical

end hinge with long

 

stem track roller

 

tracks

 

 

 

Strut (A-symmetrical) side view

Long leg

Short leg

Right double graduated

1/4”-14 x 5/8” Self tapping screw locations

end hinge with long

stem track roller

Secure top

 

 

middle

 

hole first

Left graduated end hinge

Center

Right graduated end hinge

hinge(s)

with short stem track roller

with short stem track roller

12

Top Fixtures

Tools: Power drill, 7/16” Socket driver, Phillips screwdriver

 

To install the top fixtures, align the top holes in the top fixture base with the second set of holes in the end cap of the top section. Fasten to section using (4) 1/4”-14 x 5/8” self tap- ping screws. Secure the top fixture slide to the fixture base loosely using (2) 1/4”-20 x 5/8” carriage bolts and (2) 1/4”-20 flange hex nuts.

Fasten (2) Quadrex Pan Head screws, one in the middle hole of the top fixture base and the other in the corresponding hole below the top fixture base.

NOTE: If you have 7’0” door height, use (2) #8 x 1-13/32” quadrex pan head screws.

NOTE: If you have 8’0” door height, use (2) #8 x 1-21/32” quadrex pan head screws.

The top fixture slide will be tightened and adjusted later, in step, Adjusting Top Fixture. Insert short stem track roller into top fixture slide. Repeat same process for other side.

 

(2) 1/4”- 20 x 5/8”

 

Top fixture slide

Carriage bolts

2nd Set

 

Short stem track roller

 

 

 

End cap

 

 

2nd Set

 

(4) 1/4”- 14 x 5/8”

Top fixture

 

Self-tapping screws

 

 

base

 

(2) Quadrex pan

(2) 1/4”- 20

Endcap hole pattern

head screws

Flange hex nuts

 

 

 

13

Strut (A-symmetrical)

Tools: Power drill, 7/16” Socket driver, Tape measure

 

NOTE: If an a-symmetrical strut is supplied, complete this step.

Place the a-symmetrical strut over the top rib of the top door section. Fasten each end of the a-symmetrical strut to the end cap with (2) 1/4”-20 x 11/16” self drilling screws. Fasten both wall and the long leg of the a-symmetrical strut, as shown using (2) 1/4”-14 x 5/8” self tapping screws every 30-36 inches. (Approximately 18 self tapping screws per 18’ a-symmetrical strut)

IMPORTANT: When securing the a-symmetrical strut to the top section, it is recommended not to install any fasteners into the short leg of the a- symmetrical strut.

Drawbar Operator Bracket

14 Tools: Power drill, 7/16” Socket driver, Flat head screwdriver, 7/16” Wrench, Tape measure, Pencil

Important: when connecting a drawbar operator type garage door opener to this door, a Wayne-Dalton operator/ drawbar operator bracket must be securely attached to the top section of the door, along with any strut provided with the door. The installation of the drawbar operator must be ac- cording to manufacturer’s instructions and force settings must be adjusted properly.

Position the drawbar operator bracket arm inside the top portion of the top half of drawbar operator bracket and flush against the back of the top half of drawbar operator bracket. Adjust the top holes in the drawbar operator bracket arm with the two upper holes in the top half of drawbar operator bracket.

Fasten both the drawbar operator bracket arm and the top half of drawbar operator bracket together using (2) 1/4”-20 x 9/16” track bolts and (2) 1/4”-20 flange hex nuts.

Slide the bottom half of drawbar operator bracket inside the top half of drawbar operator bracket. Adjust the both the top and bottom halves of drawbar operator brackets out against the top and bottom rib of the top section. Loosely fasten both the top and bottom halves of drawbar operator brackets together using (4) 1/4”-20 x 9/16” track bolts and (4) 1/4”-20 flange hex nuts.

NOTE: Install the 1/4”-20 x 9/16” track bolts and the 1/4”-20 flange hex nuts as far apart as possible, when positioning both the top and bottom halves of drawbar operator brackets together.

NOTE: For retro fit applications, the drawbar operator bracket assembly must be aligned with an existing drawbar operator.

Now, locate the center of the top section and align the center of the holes in the drawbar op- erator bracket assembly with the top section center line. Align the drawbar operator bracket assembly vertically.

First, secure the back of the drawbar operator bracket assembly to the top section inside surface using (2) 1/4”-20 x 11/16” self drilling screws. Next, secure the drawbar operator bracket assembly to the top and bottom ribs of the top section using (8) 1/4”-20 x 11/16” self drilling screws. Now, tighten all previously installed 1/4”-20 x 9/16” track bolts and 1/4”-20 flange hex nuts.

Secure the drawbar operator bracket assembly to the top section using (1) quadrex pan head screw.

NOTE: If you have 7’0” door height and your door width is less than or equal to 16’0”, use (1) #8 x 1 21/32” quadrex pan head screw.

NOTE: If you have 7’0” door height and your door width is greater than 16’0”, use (1) #8 x 1 13/32” quadrex pan head screw.

NOTE: For door heights greater than 7’0”, use (1) #8 x 1 13/32” quadrex pan head screw.

(2) 1/4”-20 x9/16” Track bolts

Top rib

 

and (2) 1/4”–20 Flange hex nuts

 

 

Drawbar operator

Top half of drawbar

Top

bracket arm

section

operator bracket

 

inside

 

 

 

 

 

 

surface

(4)1/4”-20 x9/16” Track bolts and (4) 1/4”–20 Flange hex nuts

Top half of drawbar

operator bracket

9

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer,

refer to your local yellow pages business listings or go to the Find a Dealer section online at www.Wayne-Dalton.com

Image 9
Contents B l e O f C o n t e n t s 6100Representations of the door parts. Each specific door Important Safety Instructions Tools Required Lock Section can be identified by #2 graduated end hinges Attempt is made to start removing an existing doorFound not to be sound, must be replaced Mounting surface with nailsRadius track 14-1/2 368 mm 12-1/2 318 mm LHR Kit 229 mm Headroom RequirementsPage Lift Handles Pull HandlesTools None Vertical Tracks Bottom SectionStacking Sections Level, Step ladderTop Fixtures Strut A-symmetricalDrawbar Operator Bracket Horizontal Tracks/Q.I. Flag Angles Top SectionHorizontal Tracks/F.A. Flag Angles End Bearing BracketsTorsion Spring Attachment Center Bracket Bushing AssemblyTape measure, Pencil Tools Step LadderSecuring Door for Spring Windings Counterbalance Lift CablesWinding Springs Rear Back Hangs This manualCheck the door for level To 7/8 16 Bolts and nuts Perforated angleDoor Arm Hookup Inside LockPull Down Rope Wood Maintenance and Refinishing Touch up where necessaryFollowing cleaning solution is recommended Use in general cleaning of garage doorsPage Lifetime Limited Warranty Model Warranty