Harmar Mobility RPL600, RPL400 manual Verifying Operation of the Lift

Page 12

12

Verifying Operation of the Lift

Caution: Complete the following section before training the customer to use the lift.

Step 1

Run the lift up and down for 5 complete cycles. Hold the direction button down and allow the limit switches to stop the lift. At the top, verify that the platform stops level with the upper landing. At the bottom, verify the access ramp unfolds and rests on the ground.

Step 2

Verify the operation of the Emergency stop switch. When this switch is pushed the lift should not run in either direction. When this switch is pulled back out, the lift should operate normally.

Step 3

Verify the operation of the sensor pan underneath the platform. Start with the lift at the top landing. Press up on the sensor pan. While holding the pan in this location, press the down switch on the platform. The lift should not run.

Warning: Do not run the lift if anyone is under the platform.

Image 12
Contents G H L a N D E R Table of Contents Using the ManualWhen You Receive the Lift SpecificationsSafety Code Requirements Site RequirementsRequired tools Required materialsPreparing to Install the Lift Controller Harness ConnectionsInstalling the Platform StepInstalling the Outer Guard Panel Installing the Ramp Anchoring the Lift StepSetting the Limit Switches Step Verifying Operation of the Lift Manual Override Top Landing Gate optional Top Landing EMI Interlock optional EMI InterlockFascia Panel optional Residential Platform Lift Owners Section Read the manual thoroughly before operating the liftSafety Controls Emergency StopDown Operating the Lift Down How did you hear about Harmar? Purchased my Harmar lift becausePlease rate your satisfaction with your Harmar dealer